AVENTICS | EV07 | R414001175–BAL–001–AB | English
Damage to components
Solvents and aggressive detergents will destroy the surface, labeling and seals of
the device!
O Check that all seals and plugs for the plug connections are firmly fitted so that
no humidity can penetrate the EV07 pressure regulator during cleaning.
O Only clean the device using a slightly damp cloth. Only use water to do this
and, if necessary, a mild detergent.
Maintaining the EV07 pressure regulator
In normal ambient conditions
In normal operation, the EV07 pressure regulator is maintenance-free.
O However, the system-specific maintenance intervals must be observed.
In aggressive ambient conditions
The seals in the EV07 pressure regulator may age faster under aggressive ambient
conditions.
O Every now and then, check that the seals on the pressure regulator are in perfect
order. A damaged seal can be recognized by parts of the seal visibly protruding
from the housing gaps. Defective seals will lead to pneumatic leaks and non-
compliance with the IP54 protection class.
O Immediately exchange the device if the seals are defective.
O Clean the filter for the pilot (9). To do this, loosen the blanking screw on the filter.
13 Troubleshooting
Malfunction
Possible cause
No output pressure
No power supply
present
No set point stipulated
No supply pressure
available
Outlet pressure too
Supply pressure too low
low
Outlet pressure less
A load with high air
than the set point
consumption results in a
large pressure drop in the
device.
Outlet pressure does
Housing ventilation port is
not correspond to the
closed
stipulated set point
EV07 pressure
Exhaust port silencer is
regulator does not
clogged
exhaust
EV07 pressure
Pilot exhaust opening is
regulator response to
closed
changes in the set
point are slow
Air is audibly escaping Seal at the inlet connection
or outlet connection is
missing or damaged
Leakage between the EV07
pressure regulator and the
connected pressure line
EV07 pressure regulator is
not leaktight
Pneumatic connections
confused
Output pressure jumps
Set point too high
to the level of the
(> 20 mA or > 10 V)
supply pressure
NOTICE
Remedy
Connect the power supply.
Check the polarity of the
power supply.
Switch on the system
parts.
Stipulate a set point.
Connect the supply
pressure.
Increase the supply
pressure.
Reduce air consumption
Use a device with a larger
nominal width
Ensure that the housing
ventilation port is open
Make sure the exhaust port
is open
Make sure that the exhaust
opening (4) is open
Check the seal and
exchange, if necessary
With direct assembly:
Check the pressure line
connections and tighten, if
necessary
Exchange the EV07
pressure regulator
Connect the pneumatics for
the pressure lines correctly
(see „Connecting the
pneumatics")
Stipulate the correct set
point

14 Technical Data

General data
Full technical data can be found in our online catalog at www.aventics.com/
pneumatics-catalog.
Pneumatics
Linear characteristic curve of set point and regulated pressure
The operating line is exhausted at set points ≤ 0,1 (0,15) bar.
Regulated output pressure Supply pressure
0.1 – 6 bar
Max. 8 bar
0.1 – 10 bar
Max. 11 bar
Minimum working pressure = 0.5 bar + max. required secondary pressure
Electronics
Supply voltage
Input resistance
Supply voltage switched on
Current output (actual value), external
working resistance
Maximum current output
Voltage output (actual value), external
working resistance
Minimum potentiometer value
Maximum potentiometer value
Standards complied with
DIN EN ISO 4414
"Pneumatic fluid power – General rules and safety
requirements for systems and their components"
DIN EN 61010-1
"Safety requirements for electrical equipment for
measurement, control, and laboratory use – part 1: general
requirements"
DIN EN 61000-6-2 "Electromagnetic compatibility"
(interference immunity for industrial areas)
DIN EN 61000-6-4 "Electromagnetic compatibility"
(interference emission in industrial areas)
15 Appendix

Accessories

Refer to online catalog at www.aventics.com/pneumatics-catalog.
Hysteresis
0.04 bar
0.04 bar
24 V DC (±20 %)
For the supply voltage, only use a
power pack with safe isolation.
Voltage input (set point)
1 MΩ
< 400 Ω
50 mA
12 V
> 1 KΩ
2 KΩ
10 KΩ
8