SENSOR FUNCTIONAL TEST
VOLUMETRIC ULTRASONIC
Carry out the test operations in the
indicated sequence. the test operations
must be carried out within the 40 s
inhibition phase. an alarm status will be
generated (siren and blinker) once this
time has elapsed.
Shut doors, bonnet and boot
keeping 2 windows on the same
side lowered about 10 centimeters.
Arm the alarm by pressing the
button of the radio control. Make
sure that there is nothing able to
move in the passenger compartment.
Insert a hand into the passenger
compartment and wave it about on
a level with the front seat headrest.
The sensor is working properly if the
LED goes off at each movement of
the hand.
Disarm the alarm by pressing the
button of the radio control and close
the windows.
Arm the alarm by pressing the
button of the radio control and hit
the windows with the frist. The LED
has to goes on in a fixed way
without any changes.
GB
20
06DE2178B.pmd
FUNCTIONAL TEST PERIMETRIC
PROTECTION
Carry out the test operations in the indicated
sequence after having shut doors, bonnet
and boot.
Arm the alarm by pressing button
of the radio control. Wait for 40 s.
Unlock a door with the key and open
it. The siren will sound and the turn
indicators will blink. Close the door.
Disarm the alarm by pressing the
button on the radio control. The turn
indicators will flash four times (alarm
memory). The LED will switch to
flashing the alarm memory display.
Arm the alarm and repeat the test
for the other connected doors, the
bonnet and boot.
FITTING INSTRUCTIONS GLOBE 4800/4900 CAN
20
28/05/2007, 10.42