Sensor calibration menu
Use the
(DOWN) or
Sensor Detect
This function has the purpose of calibrating
the instrument according to the type of
sensor installed (Standard or Project).
The second screen indicates the time for a
sensor period and type.
Press
or
Sensor Detect
P r e s s U p / D o w n K e y
t o r u n t h e m o t o r
0 . 4 0 0 s e c .
S e n s o r : S t d
Confirm with
Once the "Sensor Detection" function has recognised a "Standard" type sensor instead of a
"Project" sensor, when the "Sensor Calibrat." menu is entered again, the menu options will
"configure" themselves according to the sensor detected.
Standard and X.. Project series
sensor menu
Sensor Calibrat
Barb. Circ.
D i v i s o r f a c t .
E x i t
Barbotin Circumference
In this row the user must enter the
circumference of the gipsy (in centimetres or
inches). Use the Table 1 provided to
calculate the circumference.
Settable values: centimetres or inches.
Default value, 33 cm.
Division Factor
If you use the 3-wire inductive sensor set
here the number of signatures of the gypsy
EV030-Radio
Sensor Calibrat
S e n s o r D e t e c t .
Barb. Circ.
E x i t
(UP) key to move around the parameters.
Select with
1000 – 1500 –2000 W Project series sensor
3 3 . 0
1
Reduction Factor
In this row the user must enter the reduction
factor. See next Table 2 for the correct value
to be entered
Default value, 57.
3 3 . 0
Sensor Detect.
P r e s s U p / D o w n K e y
t o r u n t h e m o t o r
Sensor Detect
P r e s s U p / D o w n K e y
t o r u n t h e m o t o r
0 . 4 0 0 s e c .
S e n s o r : P r o j .
menu
Sensor Calibrat
Red. Factor
E x i t
26
English
5 7 . 0