KLIMA GUARD
– Digital Thermo-Hygrometer
the product, just press any key. To remove this feature, press CLEAR but-
ton and hold, the AUTO OFF icon will disappear.
Set Alarms:
• Press and hold the SET key.
either ▲ or ▼ key to toggle the low alarm limit to "ON". Press SET key
again, the display will show
toggle the high alarm limit to "ON". Now both the high and low alarms
are activated. The user can also select either one value.
• Now press SET key again. ALARM appears and °C is flashing. Press ▲
or ▼ keys to select the parameter for the alarm: °C = temperature,
% = humidity, °C Td = dew point, °C Tw = wet bulb temperature. Press
SET key to confirm the alarm type.
• Press MODE key three times.
limit is activated). Press SET key and the value is flashing. Press ▲ key to
advance and ▼ to decrease the lower alarm value. Hold the keys for a
fast run. Press MODE key again.
limit is activated). Set the high alarm limit in the same manner.
• Press Mode key to get out of alarm value set mode. Now the product is
ready to operate with alarm feature.
• When the measured temperature meets the set values, the LED will flash
and the buzzer will sound for one minute. To stop the buzzer, press any
key. The LED will still be on since the alarm triggering condition did not
change.
• If the high alarm value is lower than the low alarm value then the alarm
is activated when the measured values are within the two adjusted
alarm values.
Calibration:
The high quality sensors are pre-calibrated in the factory and need no
calibration.
It is possible if the product is placed in a low humidity or high humidity
10
17.11.2009
15:04 Uhr
ALARM OFF appears on the display. Press
ALARM OFF. Press either ▲ or ▼ keys to
ALARM appears (when the low alarm
ALARM appears (when the high alarm
Seite 6
KLIMA GUARD
– Digital Thermo-Hygrometer
environment for a long time, the sensor will have a measuring error.
However, by return the product back to a normal environment, this error
will be rectified automatically.
Placing or hanging up the unit:
A circular opening is provided on the rear-side of the unit for hanging on
the wall. To place the unit in the standing position use the foot supplied
with the unit.
Since the humidity level within rooms can vary greatly according to the
location, mount the unit so that it will monitor the conditions in a locati-
on likely to be subject to the most problems.
Battery replacement:
Remove the foot. Open the battery compartment and insert 2 batteries
1.5 V AAA. Close the battery compartment.
Use alkaline batteries only. Observe correct polarity. Low batteries should
be changed soon to avoid the damage resulting from a leaking battery.
Batteries contain harmful acids. Wear protective glasses and gloves when
handling with leaked batteries.
Attention:
Please do not dispose of old electronic devices and empty batteries in
household waste. To protect the environment, take them to your retail
store or to appropriate collection sites according to national or local
regulations.
Measuring range:
Relative humidity:
1% to 99 % r.H.
Tolerance:
±3% from 35%-75%, otherwise ±5%
Temperature:
-40°C to + 70°C
Tolerance:
±1°C
11