3.2. LEDI
REVERSO MODEL: MAINS CURRENT/TIME CODE/DISPLAY
®
►
Connect the 230 VAC 50-60Hz mains to the twin-lead cable.
Connections are made directly on the cables outside the bracket without having to open
the case.
►
To access the pushbuttons and the start switch, unscrew and gently push down the
hatch on the bottom of the case.
►
After connecting the clock, put the switch on "ON".
3.2.1. Impulse receiver and AFNOR NFS 87500 time code receiver versions
►
Connect the cable to the output CODE of the master clock (no polarity).
3.2.2. Radio-synchronized by TDF, DCF or GPS Versions
►
No wiring required.
☛
To position your antenna, please refer to instructions on antennas
CDG020/021 or web site www.gorgy-timing.fr section user manual.
3.2.3. ASCII RS232 or RS422 Version
►
Connect the cable to the output TXD, RXD & GND of the master clock.
3.2.4. SMPTE version
►
Connect SMPTE code on the terminal marked CODE of the terminal plug (no polarity).
3.2.5. Version NTP
►
Connect the Ethernet wire on the Ethernet outlet available on the item.
3.2.6. TOP option
►
Connect the cable on the both wires outgoing from the clock: brown wire and white
wire
►
Static relay output: no polarity
►
TTL 50 ohms output: brown wire is GND, white wire is positive impulse
►
Sine wave output 1000Hz: brown wire is GND, white wire is frequency
3.2.7. ASCII RS232 or RS485 output option
►
Connect the cable marked TXD, RXD et GND on the entry of the material (master
clock, the other clock, PC, etc.)