REVERSO MODEL: MAINS CURRENT/TIME CODE/DISPLAY
®
Connect the 230 VAC 50-60Hz mains to the twin-lead cable.
Connections are made directly on the cables outside the bracket without having to open
the case.
To access the pushbuttons and the start switch, unscrew and gently push down the
hatch on the bottom of the case.
After connecting the clock, put the switch on "ON".

3.2.1. Impulse receiver and AFNOR NFS 87500 time code receiver versions

Connect the cable to the output CODE of the master clock (no polarity).

3.2.2. Radio-synchronized by TDF, DCF or GPS Versions

No wiring required.
To position your antenna, please refer to instructions on antennas
CDG020/021 or web site www.gorgy-timing.fr section user manual.

3.2.3. ASCII RS232 or RS422 Version

Connect the cable to the output TXD, RXD & GND of the master clock.

3.2.4. SMPTE version

Connect SMPTE code on the terminal marked CODE of the terminal plug (no polarity).

3.2.5. Version NTP

Connect the Ethernet wire on the Ethernet outlet available on the item.

3.2.6. TOP option

Connect the cable on the both wires outgoing from the clock: brown wire and white
wire
Static relay output: no polarity
TTL 50 ohms output: brown wire is GND, white wire is positive impulse
Sine wave output 1000Hz: brown wire is GND, white wire is frequency

3.2.7. ASCII RS232 or RS485 output option

Connect the cable marked TXD, RXD et GND on the entry of the material (master
clock, the other clock, PC, etc.)