Motor unit

This cooker hood can only be used in
combination with a mechanical ventilation
system, regardless of the brand of motor unit.
Control methods
There are two control methods:
The extraction is regulated with a switch
on the motor unit.
The motor unit is regulated with a switch
on the cooker hood.
The motor unit
The motor unit must be single phase (230 V-
50 Hz) with various speeds. Whichever
method of extraction is selected, it must never
be possible to switch the motor unit off (see
for this only the motor unit manual). The
various possibilities are often given in terms
of: medium or day setting, high or cooking
setting.
Switch types:
bipolar slide switch (MSK675 / 975)
1
3
5
9
7
S2
2
4
6
8
10
I
II
III
IV
- 4 or 10 contacts
- 2 or 4 stages
- push-on connector or solder
netsnoer + stekker
mains flex + plug
Netzschnure + Stecker
lampschakelaar
fill d'alimentation + fiche de prise de courant
light switch
Lampenschalter
interrupteur
d'éclairage
1
2
3
4
5
6
7
8
9 10 L
N
Klemmenstrook (bij aflevering)
Clamp strip (included)
Anschlussblöcke (bei Ablieferung)
Bornes de raccordement (à la livraison)
lampschakelaar
light switch
Lampenschalter
interrupteur d'éclairage
bipolar push button switch (MSK986)
- 9 contacts
- 3 stages (I, II, III)
lampschakelaar
light switch
Lampenschalter
interrupteur d'éclairage
I
netsnoer + stekker
mains flex + plug
Netzschnure + Stecker
II
fill d'alimentation +
fiche de prise de courant
III
A
L
N
9
8
7
6
5
4
3
2
1
Klemmenstrook (bij aflevering)
Clamp strip (included)
Anschlussblöcke (bei Ablieferung)
Bornes de raccordement (à la livraison)
Wiring the canopy hood
Once you have decided on the control method
we advise you to draw up a wiring diagram
and then to wire the cooker hood accordingly.
Wiring example A
Motor unit
Setting
Combination
low
I
low
medium
II
medium
high
III
high
-
IV
high
Motorunit/moteur
A1
A2
A3
A4
A5
A6
A7
A8
hoog
midden
laag
medium
high
low
mittel
niedrig
hoch
moyenne
élevée
faible
N
L
A6
A4
L
N
1
2
3
4
5
6
7
8
10
L
N
9
Because of the maximum number of wires per
pipe this method of wiring will limit the
possibilities (supply from above).
Wiring example B
Motor unit
Setting Combination
night
I
night or low
day low II
low or high
day high III
low or high
- IV
low or high
Motorunit/moteur
B1
B2
B3
B4
laag
nacht
hoog
high
low
night
Nacht
hoch
niedrig
faible
nuit
élevée
dag
day
Tag
jour
L
N
hoog
high
hoch
nacht/ night/ Nacht/ nuit
élevée
B2
B3
L
N
1
2
3
4
5
6
7
8
10
L
N
9
hoog
high
hoch
laag/ low/ niedrig/ faible
élevée
B4
B3
L
N
1
2
3
4
5
6
7
8
9
10
L
N
Electrical connection
Remove the screening plate (in some
models).
Remove the attached flex and plug if the
ventilation unit is to be operated via the
canopy hood.
Make the electrical connection according
to the wiring diagram you have drawn up.
Fix the phase to clamp L, the neutral to
clamp N, and the switching wires
according to the diagram.
Check all switch functions.