PRELIMINARY CHECKS
Before starting with the installation of the system check that the
structure which is to be automated is in good working order and
respects the local standards and regulations in force.
Automating an existing system which has sliding or balancing
problems will not solve those problems and may even make them
worse by placing more stress on weakened or damaged areas. .
To this end make sure that the rolling guides "1" and "2" slide freely
and grease all the moving parts (pins, bearings etc.) using lubricants
which maintain unaltered friction characteristics over a period of
time and are suitable for temperatures of -20 to +70°C then:
- position a clean workbench near to the rolling shutter to be
automated;
- manually move the rolling shutter to the completely closed
position (lowered rolling shutter) as shown in figure 1.
1
2
Equipment required for the installation
3
5
4
10
11
Fig. 1
1
2
Fig. 2
7
8
6
12
13
Equipment:
3
- drill
4
- 10,5 mm drill bit
5
- 12 mm drill bit
6
- 6 mm Allen key
7
- 17 mm spanner
8
- 16 mm spanner
9
- 10 mm spanner
10 - type 2 small flat-nosed screwdriver
11 - type 3 medium Phillips screwdriver
12 - pliers
13 - wire strippers
14 - scissors
INSTALLATION INSTRUCTIONS
18
17
15 - centre of the rolling shutter support shaft;
16 - Ø10,5 mm motor fastening hole;
17 - Ø12 mm power cable passing hole;
18 - Ø12 mm manual release cord passing hole.
• Drill a 10,5 mm diameter hole "16" vertically under the shutter
support tube at 5,5 cm from the centre of the shutter axis "15".
• Drill a 12 mm diameter hole "17" starting vertically under the
shutter support shaft and exiting at "18" at 50 cm from the centre
of the shutter axis "15.
24
22
23
19
9
Breaking down the geared motor (fig. 4/5)
• Remove the geared motor from its packaging and place it on
the work bench.
• Remove the two screws crown holding screws "19" and "20"
from the geared motor using the 6 mm Allen key "6".
14
• Carefully remove the external crown "27", making sure you don't
damage the rubber needle bearing "28" .
• Separate the two parts of the geared motor (upper body "29"
from the lower body "30") by removing the screws "21, 22, 23,
24" using the 6 mm Allen key "6".
• Unscrew the two screws "25" and "26" and take off the terminal
boards cover "31".
• Remove the hand-grip and M10 screws + washer from the
accessory bag.
9
5,5
50
15
16
20
21
25
Fig. 3
Fig. 4
26