Hilti DD 30-W Mode D'emploi Original page 21

Masquer les pouces Voir aussi pour DD 30-W:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. Unplug the supply cord from the power outlet.
2. Open the chuck by pulling the chuck locking lever upwards as far as it will go.
Check that the core bit connection end and the chuck are clean and undamaged.
3. Tip the water collector about its mounting axis as far as it will go.
4. Guide the cutting edge of the core bit into the sealing ring in the water collector from above.
5. Align the connection end of the core bit with the corresponding openings and insert it into the chuck.
6. Turn the core bit as far as it will go while applying light pressure.
7. Secure the core bit by closing the chuck locking lever.
5.2.7
Connecting the vacuum removal system
1. Make sure that the suction hose from the all-purpose vacuum cleaner is securely connected to the core
drilling machine's water collection hose. Use a hose adapter for this purpose.
2. Connect the all-purpose vacuum cleaner suction hose to the vacuum cleaner.
3. When drilling overhead, use the retaining clip on the side handle to secure the water collection hose.
5.3
Preparing to drill using the drill stand
WARNING
Risk of injury! The drill stand can rotate or topple if not securely fastened.
▶ Before using the diamond core drilling machine, secure the drill stand to the work surface with anchors
or with a vacuum base plate.
▶ Use only anchors suitable for the base material and comply with the anchor manufacturer's instructions.
▶ Use a vacuum base plate only when the work surface is suitable for securing the drill stand by the
vacuum method.
The drill stand and the machine can be fastened either using the vacuum base plate or the DD M12 S
accessory set, i.e. using an HKD-D M12x50 anchor, the DD-LR-CLS clamping spindle and the DD-LR-CLN
nut.
WARNING
Water running out presents a risk of electric shock! The spray guard cannot be used when the machine
is mounted on the drill stand. The machine is therefore not protected against entry of water when mounted
on the drill stand.
▶ Never drill in an upwards direction with the machine mounted on the drill stand!
The side handle and spray guard (if fitted) must be removed before using the machine on the drill stand.
5.3.1
Fitting the water collector holder
Drilling is permissible only under the following conditions:
The supplied water collector holder is fitted and adjusted to match the length of the core bit used.
A core bit sealing ring that matches the diameter of the core bit must be fitted in the water collector
holder.
1. Unplug the supply cord from the power outlet.
2. Push the water collector holder into the opening provided at the front of the machine until it engages with
a click.
3. Use the slider to set the correct length range for the core bit used. Set the slider to the 150 position for
core bits with a length of up to 150 mm and set it to 300 for core bits with a length of 300 mm or 600 mm.
5.3.2
Fastening the machine and drill stand with the vacuum base plate
WARNING
Risk of injury Hazard presented by a falling diamond core drilling machine.
▶ When drilling horizontally, the drill stand must be secured additionally by a chain.
*2048398*
9
2048398
English
11

Publicité

Table des Matières
loading

Table des Matières