Battery Replacement - TFA 35.1148 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
TFA_No. 35.1148_Anleitung
09.10.2017
SPHERE – Wireless weather station
13. Setting of the WeatherHub connection (only in conjunction with the WeatherHub system)
• You can connect the base station with the WeatherHub System gateway (not included). Your data will be transmitted wire-
lessly through the gateway and the Internet directly to a server. Once connected, you can monitor the values measured at
your home on your smartphone.
• Open the WeatherHub App and the overview will be displayed. Tap "Add new sensor" and scan the QR code on the back of
the base station.
• For more information and a detailed description, go to www.tfa-dostmann.de/weatherhub.
14. Positioning and mounting of the base station and the transmitter
• When placed outdoors, choose a shady and dry place for the transmitter. Direct sunlight may trigger incorrect measure-
ment and continuous humidity damages the electronic components needlessly.
• Place the base station in any room of the house. Make sure you avoid the vicinity of any source of interference such as
computer screens, TV sets or solid metal objects.
• Once the desired location is chosen, check whether the transmission from the transmitter to the base station is possible
(transmission range of up to 100m in open areas). Within solid walls, especially ones with metal parts, the transmission
range can be reduced considerably.
• If necessary choose another position for the transmitter and/or base station.
• Once the transmission is successful, you can wall mount the transmitter or place it onto a flat surface.
15. Care and maintenance
• Clean the devices with a soft damp cloth. Do not use solvents or scouring agents.
• Remove the batteries from all devices if you do not use the products for a long period of time.
• Store the devices in a dry place.

15.1 Battery replacement

• Change the batteries of the outdoor transmitter, when the battery symbol appears on the outdoor values display.
• Change the batteries of the base station, when the battery symbol appears on the indoor values display.
• Please note:
When the batteries are changed, the contact between the transmitter and the base station must be restored – so always
start a manual transmitter search or restart the instrument according to the manual.
28
17:18 Uhr
Seite 15
SPHERE – Wireless weather station
16. Troubleshooting
Problem
Solution
➜ Connect the base station to the power adapter
No display
➜ Check the power adapter
➜ No transmitter installed
No transmitter reception
➜ Check the transmitter batteries (do not use rechargeable batteries!)
Display "---"
➜ Start the manual search for the transmitter: Press the MODE button on the base station
➜ Restart the transmitter and the base station according to the manual
➜ Choose another place for the transmitter and/or the base station
➜ Reduce the distance between the transmitter and the base station
➜ Check if there is any source of interference.
➜ Activate DCF reception in setting mode (On)
No DCF reception
➜ Wait for an attempt reception during the night
➜ Choose another place for your product
➜ Check if there is any source of interference.
➜ Restart the instrument according to the manual
➜ Set the clock manually
➜ Use the RESET function
Incorrect indication
➜ Restart the instrument according to the manual
17. Waste disposal
This product has been manufactured using high-grade materials and components which can be recycled and reused.
Never dispose of empty batteries and rechargeable batteries in ordinary household waste.
As a consumer, you are required by law to take them to your retail store or to an appropriate collection site
depending on national or local regulations in order to protect the environment.
The symbols for the contained heavy metals are:
Cd = cadmium, Hg = mercury, Pb = lead
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sphere

Table des Matières