Installation
Before installation of the hood, wall breakthrough ( core drilling) must be carried
Only for extraction mode
out by a specialist firm. During planning of wall breakthrough, pay attention to
the length of the exhaust air hose. The exhaust air hose must be sufficient up to
the outside edge of the wall without any kinks.
If the exhaust air hose is routed through an external wall, the
Important!
air discharge must be covered on the outside using a cover with
automatically opening slots (not in the scope of delivery). For this,
commission the specialist firm that makes the wall breakthrough.
Wall installation
Make sure that when drilling the holes no lines are damaged.
Caution!
Observe the instruction manual for your gas cooker! If a greater
Important!
clearance than 65 cm is specified, this must be taken into
consideration.
1. First, make a horizontal mark on the wall where the lower edge of the
extractor hood will be. It should be a min. of 65 cm above the cooker.
2. In order to position the appliance exactly above the cooker in the centre,
make a second guide line on the wall (vertical line, with the aid of a spirit
level or plumb line, from the centre of the cooker to the ceiling).
Make sure that the locations marked on the wall are not visible after
installation.
3. On the line indicating the lower edge of the extraction hood, use a pencil and
carefully mark the centre on the wall.
If possible, move the cooker so that there is sufficient space to install
Important!
the extraction hood. Use a stable ladder and get a second person to
assist you.
4. Press inwards the side sliding levers on the underside of the hood and open
the filter flap.
5. Position the extractor hood with the lower edge on the horizontal line
marked and hold it to the wall so that the centre of the extractor hood and
the vertical guide line are in alignment.
Use a spirit level to check the alignment.
12
Preparation
Guide line