INSTRUCTIONS FOR DOCUMENT MANAGEMENT
The following minimum documentation is supplied with each radio remote
control:
- transmitting unit manual
- receiving unit manual
- battery charger manual
- a CE conformity declaration
- a guarantee certificate
- the radio remote control technical data sheet
- the enclosed "Limitations & Authorisations".
Make sure that the following documents have been supplied: if they are not, request
them from Autec. Please specify the radio remote control serial number.
The conditions of the radio remote control guarantee are given in the "Certificate of
Guarantee" contained in this manual.
The electronic components which have a 3 year guarantee are: E16STXEU_,
E16SRXEU_ and E16SCHEU_.
The technical data sheet shows the wiring system between the receiving unit and the
machine. It should be compiled and checked by the installer, who has the responsibility
of correct wiring. Once all necessary checks have taken place the installer must sign the
technical data sheet, which must be kept with the user's manual (always keep a copy of
this data sheet in case it is needed for administrative purposes).
The radio remote control identification and approval data is given on plates that are on
both the transmitting unit and the receiving unit.
The plates MUST NOT be removed from where they are placed or damaged
otherwise the warranty will be forfeited.
Frequency band with radio module E16STXEU1 *
Frequency band with radio module E16STXEU2
Programmable radio channel
Channel spacing
Hamming distance
Probability of non-recognition of error
Typical working range
Time of reply to commands
Time of reply to STOP
Passive emergency time
* refer to the "Limitations & Authorizations" insert to select the permitted working band and
paragraph 8 "Programming" if setting is necessary.
** refer to paragraph "Programming" in the receiving unit manual, DIP nr. 1 settings.
CERTIFICATE OF GUARANTEE
TECHNICAL DATA SHEET
IDENTIFICATION PLATES
MODULAR TECHNICAL DATA
434.040 - 434.790 MHz
or 433.050 - 434.790 MHz
869.700 - 870.000 MHz
16 (434.040 - 434.790 MHz)
32 (433.050 - 434.790 Mhz)
12 (869.700 - 870.000 Mhz)
<10 exp-11
** 0,35 / 1 sec.
25kHz
8
100 m
<100 ms
<100 ms