5.
USING THE CHARGER FOR THE FIRST TIME
Connect the charger to a 12 V lead-acid battery or to the power supply unit. Ensure correct
polarity when connecting (red = positive / black = negative).
The screen shows the Start display, with the device name and version number.
LANGUAGE
ENGLISH
following languages are available:
The selected language is adopted automatically about three seconds after the last set-
ting is selected.
5.1
WORKING DISPLAY
Status indica-
Actual
tor
battery voltage
R
8.186V
02 LP
1.00A
Charge
B a t t e r y
discharge cur-
type
rent
The bottom line shows the type of battery ('NC' for nickel-cadmium battery, 'NM' for nickel-
metal battery, 'LP' for lithium-polymer battery, 'LO' for lithium-ion battery, 'LF' for lithium-
ferum battery and 'Pb' for lead-acid battery). This means that all the important parameters
are available at a glance during a charge or discharge process.
Operating Instructions
Power Peak ® B7 EQ-BID
If you press the "EDIT / ENTER" button after connec
ting the power supply, the Language Select
menu appears.
E l a p s e d
time
01:23
+0050
Capacity indicator
or
8
36
This display provides the user with all the
necessary information during a charge or
discharge operation. The top line of the
status display shows the type of operation
("R" for Ready (battery connected), "N" for
no battery connected, "C" for charge, "D"
for discharge, "F" for finish). The charged-
in or discharged capacity is also displayed,
together with the elapsed time since the
start.