SETTING THE DISCHARGE CURRENT

CH. CURR
DC. CURR
cell count or battery voltage and the maximum discharge power. If the maximum discharge
power is exceeded, the charger's processor limits the maximum discharge current.
ENTERING THE BATTERY CAPACITY
BAT.CAP
Battery type
NiCd
NiMH
LiPo
LiIo
LiFe
Pb (lead-acid)
SETTING THE DELTA-V CUT-OFF POINT
BAT.CAP
DELTA.V

SAVING THE SETTINGS

Press the 'EDIT / ENTER' button to save the settings you have selected. The screen then
reverts to the working display.
Operating Instructions
Power Peak ® B7 EQ-BID
+1.00A
The discharge current can be selected in 0.1 A
increments. The available range is 0.1 A to 10 A. The
-1.00A
maximum discharge current varies according to the
3600mAh
The battery capacity can be selected in 100 mAh
increments up to a maximum of 2000 mAh. After this
the increment rises to1 Ah, according to the
set capacity.
Battery capacity
100 - 60,000 mAh
100 - 60,000 mAh
100 - 60,000 mAh
100 - 60,000 mAh
100 - 60,000 mAh
100 - 60,000 mAh
For NC and NiMH batteries it is possible to adjust
3600mAh
the Delta-Peak sensitivity.
08mV/C
The stated range varies according to
the battery type: