(item no. 10016655).
-
The BENNING MM 10-PV/ MM 10-1 is supplied by means of two integrated
1.5 V batteries (AA/ IEC LR6).
-
With the protective caps being attached, the safety measuring leads men-
tioned above (tested accessories, item no. 044145) comply with CAT III
1000 V/CAT IV 600 V and are approved for a current of 10 A.
-
The BENNING TA PV measuring adapter mentioned above (tested acces-
sories, item no. 10217846) complies with CAT II 1000 V AC/1500 V DC, and
with the protective caps being attached it complies to CAT III 1000 V/CAT IV
600 V.
4.
Device description
See figure 1:
The display and operating elements shown in figure 1 are designated as follows:
1 Digital display, for the measurement reading, bar graph and display for
overrange indication
2 Polarity display
3 Battery display
4 Function key (blue), for selecting the measuring function/secondary func-
tion, resp. to enable the high-frequency suppression (low-pass filter)
5 RANGE key, switchover between automatic and manual measuring range,
adjustment of the sensitivity of the voltage indicator (Lo/ Hi)
6 REL key, relative-value function, resp. MIN/MAX function, storage of high-
est and lowest measurement value
7 HOLD key, measured value storage, resp. display illumination
8 Bluetooth
®
function
9 Rotary switch, for selecting the measuring function
J Socket (positive
range (BENNING MM 10-1)
K COM socket, common socket for measurement of voltage, current, resis-
tance, frequency, capacity, temperature, continuity and diode testing
L Socket + (positive
Ω,
,Hz, µF,
M Protective rubber holster
N BENNING TA PV measuring adapter (BENNING MM 10-PV)
O LED (red) for voltage indicator and continuity test
) The automatic polarity display for DC current and voltage refers to this.
1
5.
Functions of the digital multimeter
5.1 General information
5.1.1
The digital display 1 is designed as a 4 digit liquid crystal indicator with
15 mm digit height and decimal point. The highest value displayed is
6000.
5.1.2
The bar graph display consists of 120 segments.
5.1.3
The polarity indication 2 functions automatically. Only a polarity con-
trary to the socket definition is indicated as "-".
5.1.4
The range overload will be displayed with "0L" or "- 0L".
Attention: No indication and prior warning in the event of an overload
condition! A exceeding of dangerous contact voltage (> 60 V DC/ 30 V
AC rms) is indicated by an additional flashing symbol „()".
5.1.5
The BENNING MM 10-PV/ MM 10-1 confirms each button press with a
signal sound. Invalid button presses are confirmed by a double signal
sound.
5.1.6
The nominal measurement rate of the BENNING MM 10-PV/ MM 10-1 is
3 measurements per second (sec) for the digital display.
5.1.7
The BENNING MM 10-PV/ MM 10-1 is switched on and off by the rotat-
ing switch 9 . Switch-off position "OFF".
5.1.8
The function key (blue) 4 has two functions:
Press the function key (blue) 4 to select the secondary or third func-
tion of the rotary switch position.
HFR function (low pass filter):
Press the key for approx. 2 seconds to enable or disable the HFR func-
tion (low pass filter).
The HFR function is intended for connecting a low-pass filter (high-
frequency suppression) in the V
MM 10-PV)/ µmA AC (BENNING MM 10-1) in order to filter out high-
frequency pulses e. g. at pulsed motor drives. "
display 1 . The limiting frequency (- 3 dB) of the filter is fg = 800 Hz.
When reaching the limiting frequency fg, the displayed value is lower by
a factor of 0.707 than the actual value without filter. Press the key again
03/ 2020
Device front
key, for activation of the Bluetooth
), for 10-A range (BENNING MM 10-PV), resp. for 400 mA
1
) for V, A (BENNING MM 10-PV), µA (BENNING MM 10-1)
1
BENNING MM 10–PV/ MM 10–1
interface, resp. LOG
®
and A
functions (BENNING
AC
AC
HFR
" symbol on the LC
31