Aventics INTERBUS S Mode D'emploi page 97

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 105
1
2
Fig. 13: Mounting input/output modules on the VS HF03 LG or the VS HF04, example
1 Hexagonal socket-head screws
2 E end plate
3 Seal
4 Output module
AVENTICS | INTERBUS S | R412005743–BDL–001–AD
6
3
4
3
A maximum of 6 input and/or output modules may be
mounted on one valve system. Observe the current load!
See Fig. 13 on page 97.
1. Unscrew the E end plate (2) from the bus coupler (7) or from
the last input (5) or output module (4) of the valve system
(2 hexagonal head-socket screws DIN 912 – M4 (1), wrench
size 3) and remove from the tie rods (6).
2. Screw the tie rods (6) for the input (5) or output modules (4) on
the existing tie rods (6) (2 per input (5) or output module (4)).
– Ensure that the tie rods (6) are flush with the surface!
Disassembly and Exchange
7
6
3
5
5 Input module
6 Tie rod
7 Bus coupler
97