Fig. 6 – Close water tap supply
6.2 Lighting the pilot flame (Fig. 8)
Press on the knob "G" and turn it to the left as far as the pilot flame lighting position.
Keep the knob pressed and at the same time press button "H" for ignition battery. After having lit the pilot flame keep the
knob fully pressed for approximately 10/20 seconds in order to heat the thermocouple, after which release it.
The flame can be observed from the spy hole on the front panel. Should the flame go out during or after release of the
knob repeat the operation.
H= Button ignition battery
G= Knob

6.3 Lighting the main burner

To switch on the main pilot light, turn the gas knob from the "light/pilot light" position to the "maximum flame" position and
then turn the knob to the "minimum flame" position to set a slower and more econimical cooking procedure, if required.

6.4 Turning out the main burner

To switch off the main burner and then the pilot light, turn the gas knob to "light/pilot light" and then to "closed".
At the end of the working day, switch off the gas check valve upstream of the appliance.
We recommend signing a maintenance contract at last once a year.
Clean the cooking plate after use with an emery cloth or with steel wool. After cleaning a thin layer of cooking oil has to be
applied to the plate surface in order to preserve it better.
The parts in stainless steel have to be cleaned gently, using warm water. If you use soap or detergent, make sure that
they do not contain abrasive products and that they are recommended for cleaning stainless steel.
If the appliance is not used for a certain period of time, close the gas supply cock. In the case of a fault in the appliance or
malfunctioning close the main gas inlet cock and call the technical service centre.
Each time you finish cooking empty the water by removing the overflow plug.
Avoid the formation of solids that can clog the drain.
All repairs and fault remedying must be carried out by a skilled installer.
Position
Closed
G
H

7. MAINTENANCE

Fig. 7 – Open water tap supply
Position
Lighting / pilot light
Position
Maximum flame
Position
Minimum flame