a)
Install the appliance in the required position near the water mains.
b)
Connect the mains water pipe to that of the appliance, using a mechanical filter and a shut-off cock.
Connect the appliance's exhaust pipe to a suitable heat resistant collector.
c)
The data plate is positioned on the left of the cabinet.
-
Appliance in category
-
Supply pressure: Butane/Propane (G30-G31) 30/37mbar
TABLE 1
DIMENSIONS
MODEL
mm
(L x W)
70GRG40
400x730
70GRG80
800x730
80GRG40
400x900
80GRG80
800x900
TABLE 2
FOR SERIES 700s APPLIANCES
NOMINAL CAPACITY kW 10
Liquid gas
(G30 28...30mbar)
Natural gas
(G20 20mbar)
For appliances in series 700s (800x730x900) with nominal capacity 10 + 10 = 20 kW and reduced capacity 4,5 + 4,5 = 9 kW
the injectors are double.
FOR APPLIANCES IN SERIES 900s
NOMINAL CAPACITY kW 13
Liquid gas
(G30 28...30mbar)
Natural gas
(G20 20mbar)
For appliances in series 900s (800x900x900) with nominal capacity 13 + 13 = 26 kW and reduced capacity
4,5 + 4,5 = 9 kW the injectors are double.
4. OPERATION WITH SUPPLY GAS IDENTICAL TO THAT AVAILABLE
Check whether the indications on the data plate correspond to the gas distributed. Also check correspondence to the
indications below.
4.1 Checking the supply pressure (Fig. 2)
The supply pressure can be measured by means of a pressure gauge with a
U-shaped pipe, or of the electronic type with a minimum grading of 0.1
mbar.
Unscrew the screw "A" from the pressure tap "B".
-
-
Position the pressure gauge.
Switch on the appliance and check that the pressure is the one
-
intended: otherwise check on the cause.
At the end of the operation, reassemble the appliance and check on the
-
connection.
3. TECHNICAL FEATURES
Natural gas (G20) 20mbar
GAS
GAS
CAPACITY
COUPLING
kW
10
¾" Gc ISOR7
20
13
¾" Gc ISOR7
26
400x730x900H
REDUCED CAPACITY kW 4,5
Main burner
Pilot light injectors
injectors
Ø 1/100 mm
155R*
225R*
400x900x900H
REDUCED CAPACITY kW 4,5
Main burner
Pilot light injectors
injectors
Ø 1/100 mm
180*
270R*
10
CONSUMPTION
RATE
Kg/h
0,789
1,578
1,025
2,050
By-pass
No.
Ø 1/100 mm
24*
110
29*
Adjustable
By-pass
No.
Ø 1/100 mm
24*
110
29*
Adjustable
CONSUMPTION
RATE
3
m
/h
1,058
2,116
1,385
2,751
Primary air pos.
main burner
(size in mm)
16
16
Primary air pos.
main burner
(size in mm)
16
16
A
B
Fig. 2
TYPE
A1
A1
A1
A1