4.
Technical data
4.1
Data
Model number
Nominal heat load
Space heating ability in m³ in favourable / less favourable /
unfavourable
conditions according to DIN 18893/TABLE. 2
Short-term heating
Long-term heating
Exhaust gas for fuel:
Exhaust gas mass
Exhaust gas connector temperature
Flow pressure at nominal heat load
Particles / dust (based on 13% O2)
CO ( based on 13% O2)
Efficiency
Mains current
Bulb
4.2
Dimensions
W1-75
X
30
850 (+20)
80
900 (+20)
screw feet
can raise stove height by +20 mm
Weight: Net 171 kg
The dimension shown is only for information! We reserve the right to make changes to the
construction if these improve the technical level or the quality!
A
692 (+20)
742 (+20)
B
48
W1 - 75
8 kW
260 / 145 / 98
182 / 105 / 71
Firewood / Lignite
12,2 / 8,4 g/s
249/253˚C
12 Pa
≤ 40 mg/m³
0,09 / 0,06%
1161 / 812mg/Nm
75,6 / 76,4%
230 V AC
15 W
3