Replace the roof tiles on the uncovered area of the
roof and secure each of the tiles in the rows
adjoining the left and right sides of the solar-panel
space with tile clips (44). The tiles adjoining the right
side of the solar-panel space may have to be cut.
The tiles in the rows adjacent to the roof-integral
installation must have their hooks removed on the
side next to the cover plate.
The tiles adjoining the top edge of the solar-panel
space generally have to be cut. The overlap over
the top cover plates depends on the angle of the
roof as follows:
≤ 35˚ at least 120 mm
> 35˚ at least 100 mm
> 50˚ at least 80 mm
28.
A tile clip (44) must be fitted to each tile in the two
rows adjoining the sides of the solar-panel
space. The tile clips fit around the tiles and
should be fitted on the side next to the cover
plate.
29.
To the left or right (see Section 7) of and below
the solar-panel space, a vented roof tile (not
supplied) should be fitted so that the piping and
sensor cable can be passed through the roof.
Note:
The vent hole in the vented tile must be large
enough for the connecting hoses together with
heat insulation and the sensor cable.
Remove the protective film from the butyl strip on
the lead skirts of the lower cover plate. Stick it
against de roof tiles.
Note:
The butyl strip is highly adhesive – once the lead
skirts are stuck in place, their position cannot be
adjusted.