Dual User Mode; Time Delay Mode; Floor Mount - SentrySafe DH-134E Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dual user mode

3
For additional security set your safe to dual user mode. This feature requires one user to enter their code and within sixty (60) seconds, a second user must
enter thier code to unlock the safe. Always perform this operation with the door open.
Any Code + Any Code to unlock
1. Enter: # - Master Code - # - 1 - # - 1 - #
2. The lock will indicate a valid setting change
with a single signal.
Master or Manager Code + User Code to
unlock
1. Enter: # - Master Code - # - 2 - # - 2 - #
2. The lock will indicate a valid setting change
with a single signal.

Time delay mode

4
Always perform this operation with the door open. This function will delay both the opening and programming of the lock.
Activate time delay
1. Enter: # - Master Code - # - (01-99) - # -
(01-99) - #
2. The lock will indicate a valid setting change
with a single signal.
Example: # - Master Code - # - 05 - # - 05 - #,
this will set a five (5) minute time delay.
3. Press * or # to initiate the Time Delay.

Floor Mount

5
(optional)
This kit contains:
• Four (4) Masonry Anchors
Required tools:
• Safety Glasses
• Powered Drill
• Adjustable Wrench
• 1/2 in. (M12) Masonry Drill
Opening your safe in dual user mode
1. Enter: * - 1st Code - # - 2nd Code - #
2. The lock will indicate a valid code entry with
a single signal and the open light will stay
green for five (5) seconds.
3. Turn the handle clockwise before the green
light disappears
When time delay is set
(During the time delay period the keypad will
not respond to any entries)
The lock will flash once every five (5) seconds
during time delay and will flash once every
second during the last ten (10) seconds of the
time delay ending with a double signal.
The lock will flash twice every five (5) seconds
during the open period. The open period length
is two (2) minutes.
Instructions:
1. Unlock safe and open door.
2. Remove safe floor carpet.
3. Look on the bottom of safe for four (4)
holes with cap plugs.
4. Remove the cap plugs.
5. Position the safe in the desired location.
6. From inside the safe mark the location of
the four (4) bolt down holes.
7. Move the safe aside to the clear marked
spots for drilling.
2
Returning to single user mode
(Single code to unlock)
1. Enter: # - Master Code - # - 0 - # - 0 - #
2. The lock will indicate a valid setting change
with a single signal.
During the open period you can unlock or
program your safe.
Deactivate time delay
1. Enter: # - Master Code - # - 00 - # - 00 - #
2. The lock will indicate a valid setting change
with a single signal.
8. Using the ½ in. masonry drill, drill a 4 in.
deep hole in the marked locations.
9. Replace the safe in the desired location
with the holes in the safe aligned with the
drilled holes in the floor.
10. Pass each masonry anchor through the safe
floor into the drilled holes; making contact
with the safe floor.
11. Tighten each masonry anchor with the
adjustable wrench.
12. Replace safe floor carpet.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dh-074eDh-109e

Table des Matières