GB
adapter provided (13) to the two-pole plug (12). Once the operating
voltage has been applied, the camera will be switched on.
CAUTION
5.2 Aligning the camera and adjusting the lens
Switch on the monitor for checking the settings and align the camera to
the surveillance zone: for turning, tilting and panning the camera, re-
lease the locking screws (3) for the corresponding axes (matching
screw keys are provided) and fasten them again after aligning.
The arrow buttons of the remote control (9) are used as zoom and
focus buttons: Adjust the image section with the buttons
[
= to reduce the focal length,
focus the image with the buttons
focussing will also be possible via the RS-485 interface
6 Settings in the OSD Menu
Settings in the two-page OSD menu will be made via the remote con-
trol (9). To activate the menu, press the button SET (a). The first menu
page SETUP will appear:
LENS
SHUTTER
WHITE BAL.
BACKLIGHT
AGC
DNR
SENS-UP
SPECIAL↵
EXIT
Select the menu item with the button
the button
22
When darkness falls, the infrared LEDs will be
switched on. Never look directly into the lit LEDs at a
close range. Although the infrared light is invisible, it
may cause eye damage.
SETUP
AUTO↵
— — —
ATW↵
OFF
MIDDLE↵
LOW
OFF
(c). An arrow ↵ behind a menu item or a setting op-
or
= to increase the focal length] and
and
(b). (Note: Zooming /
or
(b). Change a setting with
and
(c)
chapter 5.1.)