Product Description - Sunsystem BURNit PelleBurn PLB 15 Instructions D'installation Et D'exploitation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Customer must undergo boiler operation/
maintenance
installer/service shop.
EN
Safety rules for user operation:
- Operate the pellet burner on recommended fuel
only, and to that end you must regularly inspect the
boiler room.
- Do not use flammable liquids for ignition or increase
of burner output.
- Clean the burner surface using non-flammable
agents only.
- Do not place flammable objects onto the burner
housing and heating boiler cabinet or in their
proximity. (see diagram 1 for the minimum
clearances)
- Do not store flammable materials in the boiler room.
- It is mandatory to strictly observe instructions for
connecting the burner to power network as well as
to all peripherals.
- Structural changes to Dual-chamber boiler by user
can cause damage to equipment or injury.
- Do not allow contact transmission of electrical wire
or touch any part of the boiler, where the surface
temperature can exceed 70°C.
- This manual should be kept throughout the lifetime
of the boiler.
CAUTION! Hot surface!
Risk of burns if you touch the running
system. Burner housing, body and flange
are hot surfaces during burner operation.
It is strictly prohibited to open boiler
inspection doors with the burner running.
The hopper hatch cover is not allowed to
remain open for longer periods of time.
Also, exercise caution when touching the
observation port for monitoring the burning
process. It may be hot.
1.2.3. Minimum clearances for installation and
flammability of construction materials
The applicable minimum clearances in your country
may differ from the ones specified below. Please,
consult your installer.
The minimum distance from the burner, heating
boiler or exhaust gas pipe to objects or walls must be
at least 200 mm.
TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
training
by
authorized
Table 2. Flammability of construction materials
Stone, bricks, ceramic tiles, baked
Class А – non-
clay, solutions, plaster free of
flammable
organic additives.
Gypsum board panels, basalt fiber
Class B – hardly
needled
flammable
AKUMIN, Izomin, Rajolit, Lignos,
Velox, Heraklit.
Class С1/
Wood beech, oak. Wood softwood,
С2 – Medium
layered wood
flammable
Asphalt, cardboard, cellulose, tar,
Class C3 – easy
fiberboard,
flammable
polyethylene.
For general safety considerations, we recommend
that the boiler be placed on a foundation made of
class A material, see table 2.
Diagram 1. Recommended clearances
between boiler and walls /see page 59/

2. PRODUCT DESCRIPTION

Ecological and highly-efficient pellet boiler PelleBurn
is designed for firing wood pellets. The mantle fully
covers the combustion chamber. Efficiency rate
reaching 91%. Approved in accordance with EN 303-
5, class 5. Set includes pellet boiler, pellet burner,
auger and pellet fuel hopper (option).
2.1. Design structure of boiler PelleBurn.
Cylindrical body design is made of high-quality
boiler steel sheets with thickness of 4 mm for the
combustion chamber and 3 mm for the water mantle.
• Ecological. A high-end pellet boiler. The wood
pellets used for fueling the boiler are a renewable
fuel with minimum carbon emissions and ultimate
burning efficiency.
• Automated. Owing to an improved algorithm
with optional adjustment of a wide variety of
parameters, the system may befinely tuned to
any particular heating system to achieve optimum
efficiencyand fuel consumption.
Controller functions:
1) fully automated ignition and pellet feed;
2) exhaust fan ensures stable operation of the
boiler;
3) boiler-and-burner self-cleaning function;
4) controls the operation of central heating
circulation pump;
5) controls the operation of DHW (domestic hot
water) pump;
6) controls by room thermostat;
7) flue gas sensor
4
felt,
fiberglass
board,
cork,
polyurethane,

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Burnit pelleburn 25Burnit pelleburn 40

Table des Matières