Mounting Of Fuel Hopper Fh 500; Warranty Terms; Technical Features; Technical Features Of Pelleburn Pellet Boiler - Sunsystem BURNit PelleBurn PLB 15 Instructions D'installation Et D'exploitation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
priority. Only when its preset value is reached, the CH
circulation pump will start.
Important – The use of "External room
thermostat for the burner" option
(Thermostat) is active only if option is
selected (CH Priority – priority of central
heating installation pump).
10.2.3. Burner shut-down „Standby"
menu and confirm the selection by pressing "F". The
burner goes into extinguishing mode. Set the
temperature to start heating pump.

11. MOUNTING OF FUEL HOPPER FH 500

Fuel hopper FH 500 has a capacity of 500 liters
pellets. Its design allowing installation by choice on
either side of boiler. An important condition is to be
leveled. Before loading the pellets, make sure that
the hopper is clean. Empty the container for pellet
powder and dust.
Fuel hopper hatch-cover must be closed during
operation. Detailed description for the assembly of
a fuel hopper FH 500 will find the User manual for
assembling the fuel hopper FH 500.
Water side pressure drop (ΔT = 20°C)
Pellet burner Pell
Pressing the "F" button will
take you to the main menu and
by using the navigation arrows
you can select the "Standby"
13.1.2. Technical parameters of PelleBurn pellet boiler
Nominal heat output
Min / Max heat output
Height H
Width L / Depth D
Mantle volume
Combustion chamber volume
Combustion chamber resistance
Required chimney draught
Insulation
Electric power supply
Recommended fuel
Operating temperature range
Operating pressure

12. WARRANTY TERMS

The warranty terms are described in the Service
booklet included in the supply.

13. TECHNICAL FEATURES

13.1. Technical features of PelleBurn pellet boiler

13.1.1. Elements of PelleBurn pellet boiler
Diagram 23. Elements of PelleBurn pellet
1. Housing
2. High efficiency thermal insulation
3. Chimney
4. Flue gas extraction fan
5. Fume exhaust tube
6. Automatic cleaning system
7. Water mantle
8. Combustion chamber
9. Ash-and-soot container
10. Burner housing
11. Pellet burner
12. Burner flange
13. Controller unit
14. Ash and soot transport screw with stirring
mechanism
PelleBurn 15 PelleBurn 25 PelleBurn 40
kW
kW
mm
mm
640/1120
l
l
Pa/mbar
10/0,10
Pa/mH
O 480/0,048
2
Pa
100 mm high-efficiency thermal wool
Boiler
Doors
20 mm high-efficiency black veil rockwood
V/Hz/A
230/50/10
wood-pellets, diameter 6÷8 mm
°C
bar
Weight
kg
Power
kW
17
boiler /see page 66/
15
25
5÷15
8÷25
1290
1430
640/1120
55
70
43
53
11/0,11
850/0,085
10÷20
10÷20
lined with aluminum foil
230/50/10
65-85
65-85
3
3
220
240
5÷15
8÷25
EN
40
10÷40
1700
700/1120
101
73
12/0,12
1350/0,135
10÷20
230/50/10
65-85
3
358
10÷40

Publicité