Technical Data
Current DC
Range
40 A
400 A
Current AC
Range
40 A
400 A
Voltage AC
Range
400 mV
4 V
40 V
400 V
600 V
Voltage DC
Range
400 mV
4 V
40 V
400 V
600 V
Continuity Test
Range
•)))
Resistance
Range
400 Ω
4 kΩ
40 kΩ
400 kΩ
4 MΩ
40 MΩ
30
Resolution
0,01A
0,1 A
Resolution
0,01A
0,1 A
Resolution Accuracy
50 Hz...500 Hz
0,1 mV
±(1 % rdg. + 3 D)
(40...60 Hz)
1 mV
±(1 % rdg. + 10 D) 11 MΩ
10 mV
±(1 % rdg. + 3 D)
100 mV
1 V
±(1,2 % rdg. + 3 D)
Resolution Accuracy
0,1 mV
+(0,8 % rdg. + 5 D) 100 MΩ
1 mV
10 mV
±(0,8 % rdg. + 2 D)
100 mV
1 V
±(1 % rdg. + 2 D)
Sound
Test Voltage
< 30 Ω
approx. 1,5 V DC
Resolution Accuracy
0,1 Ω
±(1 % rdg. + 5D) app. 1,5V DC
1 Ω
10 Ω
±(1 % rdg. + 3D) approx.
100 Ω
1 kΩ
10 kΩ
±(3 % rdg. + 3 D)
Accuracy
±(2,5 % rdg. +
+ 10 Digits)
Accuracy
±(2 % rdg.
+ 10 Digits)
Input-
impedance
100 MΩ
10 MΩ
Input-
impedance
11 MΩ
10 MΩ
Overload Protection
600 V
Test Voltage Overload Prot.
0,45 V DC
Overload Prot.
600 A (1 min.)
Overload Prot.
600 A (1 min.)
Overload Prot.
660 V AC/DC
Overload Prot.
660 V AC/DC
600 V AC/DC
( 1 min.)