All operating elements and connections de -
GB
scribed can be found on the fold-out page 3.
1 Operating Elements
and Connections
1.1 Microphone IRS-2..HT
1 IR transmitter
2 Power switch: keep pressed for a while;
the lighting colour will indicate the battery status:
green = sufficient; red = low
3 3.5 mm input jack to connect a tie clip / headband
microphone or a unit with line signal level (e. g.
MP3 player),
when the jack is connected, the internal micro-
phone will be deactivated
4 Mute button
lower position (MUTE) = sound off
upper position (TALK) = sound on
5 Inside the battery compartment: Switch to select
the IR transmission channel
Channel A (2.3 MHz), factory-set on IRS-200HT
Channel B (2.8 MHz), factory-set on IRS-202HT
6 Inside the battery compartment: Switch to select
the transmission power: HI or LOW
7 Latch of the battery compartment cover: to
unlock the cover, push the latch towards the
microphone head
1.2 Sensor IRS-200IR
8 Bracket for wall / ceiling mounting via four drill
holes
9 F standard jack to connect one of the SENSOR
jacks (22) of the IRS-200TXA via the 10 m cable
provided
10 Locking screws to adjust the inclination angle
11 IR sensor
12 Power LED of the IR sensor (11)
1.3 Active speaker system IRS-200TXA

1.3.1 Front panel

13 IR sensor
14 Power LED of the IR sensor (13)
15 On / off switch and volume control for the IR
transmission channel A
16 Status LED of channel A (red = channel acti-
vated, green = reception of IR signal)
17 Audio signal LED of the receiver: starts to light
up from a specific signal level, depending on the
10
volume controls for channel A (15) and channel
B (19)
18 Status LED of channel B (red = channel acti-
vated, green = reception of IR signal)
19 On / off switch and volume control for the IR
transmission channel B

1.3.2 Rear panel

20 Control MASTER for the total volume
21 Control TONE to adjust the sound
22 F standard jacks to connect up to two external
IR sensors IRS-200IR to extend the IR trans-
mission range
23 Volume control for the input AUX IN (27)
24 Volume control for the input MIC IN (26)
25 Mono output with line signal level (via 3.5 mm
stereo jack) to route the mixed signal, e. g. to a
second active speaker system
Note: The controls MASTER (20) and TONE (21) will
not affect the AUX OUT signal.
26 Input MIC IN (via 6.3 mm mono jack) to connect
a microphone
27 Input AUX IN (via 3.5 mm stereo jack) to con-
nect an audio source with line output level, e. g.
CD player
28 LED CHARGE: will light up when the active
speaker system has been connected to a mains
socket via the power supply unit
red: battery being charged;
green: battery fully charged
29 POWER switch: will light up during operation;
if it starts flashing during battery operation,
recharge the battery
30 Low voltage jack DC IN to connect the power
supply unit provided
31 Cover of the battery compartment

2 Safety Notes

The units of this system correspond to all relevant
di rectives of the EU and are therefore marked
with
.
WARNING The power supply unit uses danger-
ous mains voltage. Leave servicing
to skilled personnel only. Inexpert
handling of the unit may result in
electric shock.
Please observe the following items in any case:
G
The units are suitable for indoor use only. Protect
them against dripping water and splash water,
high air humidity and heat (admissible ambient
temperature range (0 – 40 °C).