Starting up the machine
(Fig.3)
Turn the main switch (Q1) to position "1" in order to put the machine under tension. To start up the
motor push set the 'Star-Delta' switch in the 'Star' position and push the button S1, after about 8 sec.
turn the switch to the 'Delta' position. For the optional ' A uto-Star-Delta' push the start button (S1),
the motor starts-up automatically in Star-Delta. By pushing the stop button (AU1) the main motor is
automatically stopped, and slowed down by the automatic brake within 10 seconds.
The feeding motor can be started by pushing the button (POT) of the potentiometer, and by turning the
same button the feeding speed can be chosen from 5 to 22 meters per minute.
To stop the feeding motor, push the same button (POT). All motors are stopped automatically when the
emergency stop button (AU1) is used; Make sure the brake release switch (S4.1 ) is set at position O
and the warning light inside the same button is not lit, in order to be able to start up the machine.
When this same switch is pushed during the run of the machine the motors will automatically be
stopped.
WARNING:
All fuses can be found inside the electrical cabinet, and each time this cabinet is
opened the machine must be disconnected from the main power supply.
Start main motor S1
Break release S4.1
Digital readout
Emergency stop
Table up slow S7
Table up fast S5
Pan switch Q1
Table down fast S5
Table down slow S8
RESET feeding
Warning light speed thicknesser L2
Feeding speed thicknesser POT
Standard manual
Fig.3
Fig.3
'Star-Delta'
46
V1112 D 630
Nederlands
Français
English
Deutsch