OPERATION
Always turn off the air supply, drain
hose of air pressure and detach tool
from air supply before installing,
removing or adjusting any part or
accessory on this tool, or before per-
forming any maintenance on this tool.
Never operate the tool without a Chisel
Retainer.
Never use a chisel as a hand struck
tool. They aredesigned and heat treat-
ed to be used only in air hammers.
Select the correct shank and retainer
for the tool.
Never use dull, chipped or damaged
accessories. Never cool a hot acces-
sory in water as brittleness and early
failure can result.
Accessory breakage or tool damage
may result from prying. Take smaller
bites to avoid getting stuck.
The Quick Change Chuck is designed to
accept only 0.401" diameter round shank
chisels. Always place the chisel in the
hammer's quick change chuck retainer
and hold the tool down to the work
WARRANTY
Important: DO NOT RETURN DEFECTIVE PRODUCT OUTSIDE OF ORIGINAL ONE (1) YEAR WARRANTY PERIOD TO
PLACE OF PURCHASE.
WARRANTY POLICY:
from the date of original purchase. We will replace, at our option, any part which proves to be defective in material or workman-
ship. Repairs or replacements are warranted as described above for the duration of the original warranty period. In the unlikely
event a replacement unit is required during this One (1) year period, return the unit to your local NAPA Auto Parts Store for a
replacement. This warranty does not apply to products which have been subjected to abuse, misuse, modification, neglect, lack of
maintenance, use in a production-related service, or repaired by anyone other than an Authorized Carlyle Air Tool Service Center.
For complete listing of Authorized Master Repair Centers, see enclosed Customer Warranty Repair Form, or
visit www.toolwarrantyrepair.com
PLEASE REVIEW ALL WARNING INSTRUCTIONS PRIOR TO OPERATION. SAVE THIS MAN U AL FOR FUTURE REF ER ENCE.
6-1020A
before operating. Damage to the tool or
the retainer may result if this precaution is
not followed.
The chisel retainers are not designed for
complete
release of chisels or hammers. To avoid
injury, the throttle must never be
depressed unless the chisel is held firmly
against the work place. When tool is not
in actual use, the chisel must be removed.
When using tool, regulate the speed so
that the chisel is not being driven out of
the cylinder. If piston is allowed to strike
the cylinder wall, internal damage will
result.
To change chisel, pull back on quick
change chuck collar and insert chisel.
Release chuck collar to lock in the chisel.
To regulate power, gently pull the variable
speed trigger for minimum to maximum
power.
NOTE: During operation, safety gog-
gles should always be worn to guard
against flying debris (users and
bystanders).
This Carlyle Air Tool is warranted against defects in material and workmanship for a period of One (1) Year
safety
against
accidental
5
Specifications
Overall Length ........................... 6.75"
Weight .................................... 3.5 lbs.
Blows per Minute ............. 3,500 SPM
Chisel Shank Diameter ............ 0.401"
Sound Level ....................... 110.9dBa
Vibration Level ..................... 14.8m/s2
Air Consumption ................. 12.1CFM
Air Inlet Thread Size ............ 1/4" NPT
Recommended Hose Size ....3/8" I.D.
Recommended
Air Pressure ................. 90psi (6.2 bar)
Rev. 09/10/19