GENERAL SAFETY PRECAUTIONS

This installation manual is intended for professionaly competent personnel only.
The installation, the electrical connections and the settings must be completed in conformity with good workman-
ship and with the laws in force. Read the instructions carefully before beginning to install the product. Incorrect
installation may be a source of danger.
Packaging materials (plastics, polystyrene, etc) must not be allowed to litter the environment and must be kept
out of the reach of children for whom they may be a source of danger. Before beginning the installation check that
the product is in perfect condition.
Do not install the product in explosive areas and atmospheres: the presence of flammable gas or fumes repre-
sents a serious threat to safety. The safety devices (photoelectric cells, mechanical obstruction sensor, emer-
gency stop, etc) must be installed taking into account: the provisions and the directives in force, good workman-
ship criteria, the installation area, the funtional logic of the system and the forces developed by the motorised door
or gate.
Before connecting to the mains check that the rating is correct for the destination power requirements.
A multipolar isolation switch with minimum contact gaps of 3 mm must be included in the mains supply.
Check that upstream of the electrical installation there is an adequate differential switch and a suitable circuit
breaker.
When requested, connect the motorized door or gate to an effective earthing system carried out as indicated by
current safety standards. During installation, maintenance and repair operations, cut off the power supply before
opening the cover to access the electrical parts.
The electronic parts must be handled using earthed antistatic conductive arms. The manufacturer of the motorising
device declines all responsability in cases where components which are incompatible with the safe and correct
operation of the product only original spare parts must be used. For repairs or replacements of products only original
spare parts must be used. The fitter must supply all information corcerning the automatic, the manual and emergency
operation of the motorised door or gate, and must provide the user the device with the operating instructions. It is
recommended that antistatic conductive earthed arm bands be worn when manipulating electronic parts.

INSTALLATION WARNING

Secure the electric board permanently. Drill the lower side of the container so as to run the cables through it.
Secure the cables, if they are accessible, by means of appropriate gland plates (not provided by us). Keep the line
conductors separate (at least 8 mm.) from the control conductors and motor at the terminal board connection
points (for example, by means of clamps). Re-close the container by means of the 4 screws, taking care to
properly position the cover (lower side = Devoid of gasket).

TECHNICAL DATA

Power supply
Motor output
Safety accessories power supply
(nominal)
(peak)
Temperature
Degree IP
Dimensions
All right reserved
All data and specifications have been drawn up and checked with the greatest care. The manufacturer cannot however take any
responsibility for eventual errors, ommisions or incomplete data due to technical or illustrative purposes
D2H
230 V~ / 50 Hz
24 V= / 2 x 4.5 A (max)
24 V= / 0.3A
24 V= / 0.5A
-15 °C / +50 °C
IP54
180x250x100
5
DITEC S.p.A. - IP1586 - D2H