Technical data

The technical data can be found on the name plate on the
housing.
f Observe the technical data on the name plate.
f Only use the charging cable up to a height of 4,000 m
above sea level.
Operation
T
WARNING
Damaged charging cable – Danger to life by electric
shock
A damaged charging cables can result in death or severe
injury.
f Check the charging cable for damage (e.g. cracks) prior
to every use.
f Do not use damaged charging cable.
T
ATTENTION
Property damage due to fire
A too high charging current can damage the charging
cable and cause a fire.
f Observe the maximum permissible charging current in
the country of use.
Maximum permissible charging current
The maximum permissible charging current is, for
instance, 6 A in Denmark and 8 A in Finland or
China.
Starting the charging process
Observe the cover page – Figure 2, 4 and 5.
f Unroll the charging cable.
f Remove the protective cap from the plug on the vehicle
side.
f For plugging in the charging cable, observe the se-
quence in Figure 2.
f Start charging the vehicle.
Self-test function
The self-test function of the charging cable when
plugging the charging cable into the charging
infrastructure checks all important parameters
and only enables the charge, if all test criteria are
fulfilled.
Temporary power failure
In the case of temporary power failure, the charg-
ing process will be automatically continued after
the voltage is restored.
6
Terminating the charging process
„ Once the vehicle has been charged, stop the charging
process.
Observe the cover page – Figure 3 and 4.
Information on type GB and type 1:
f Press the release button when unplugging the
charging cable.
f End the charging process on the vehicle.
f For unplugging in the charging cable, observe the se-
quence in Figure 3.
f Put the protective cap on the plug on the vehicle side.
f Wind up the charging cable without kinking.
f Store the charging cable properly in your vehicle.
Status of the light-emitting diodes (LEDs)
LED 1
LED 2
Status
flashes
flashes
blue
blue
flashes
flashes
Self-test function active.
orange
orange
flashes red flashes red
lights up
No vehicle connected.
off
blue
flashes
off
Vehicle connected.
blue
flashes
flashes
Charging process active.
blue
blue
Operating temperature critically
high.
flashes
off
9 Charging will be continued with
orange
Î see
Operating temperature exceeded.
lights up
off
9 Charging will be stopped.
orange
Î see
off
flashes red
Fault current occurred.
Faults in the charging infrastruc-
ture.
f Have protective conductor
lights up
flashes red
red
flashes red
flashes red
alternately
alternately
Errors in the charging cable.
Î see
lights up
lights up
red
red
reduced charging current.
1)
1)
(PE) or charging infrastructure
checked by a qualified electri-
cian.