INSTALLATION
1. First of all, make sure that the supplied voltage matches the voltage
marked on the base of the laser unit;
2. Installation should be made by an experienced technician. Fasten the
laser unit and adjust the angle of the laser light to suit your needs.
3. Please check that the fan and the ventilation holes are not blocked;
4. A hole is provided to secure the unit with an additional safety cable if
the unit is installed on the ceiling. Make sure that the safety cable and
mounting place can carry at least 10 times the weight of the unit.
5. The laser unit should be securely installed.
6. For safety reasons, the unit must be earthed.
Function setting
Use the dipswitches to assign the unit's function: DMX/slave, sound
active or AUTO mode. For DMX mode, set the DMX address. Each
dipswitch represents a binary value. See the "Function chart".
1=ON X=OFF
DIPSWITCH CHART
#1
#2
#3
#4
#5
#6
#7
X
X
X
X
X
X
X
1
X
X
X
X
X
X
1
1
X
X
X
X
X
X
X
1
X
X
X
X
1
SET DMX ADDRESS FOR DMX
MODE
Sound Active
The change of the laser pattern is controlled by sound. That means the
rhythm of the sound controls the change of the laser pattern. Turn the
sensitivity knob in the clockwise direction to increase the fixture's
sensitivity to sound, turn the knob in the counterclockwise direction to
decrease.
AUTO
Auto cycles the built-in programs without being controlled externally.
DMX Control
The system only accepts the DMX512 signal of international standard to
control the system mode, the laser pattern ON /OFF, the size, the position,
the speed, etc.
Master-Slave Operation
This mode will allow you to link up to 32 units together without controller.
1. Install the units in a suitable position (laying or appending).
© Copyright LOTRONIC 2012
FUNCTION
#8
#9
#10
X
X
X
SOUND ACTIVE
X
X
X
AUTO -beam
X
X
X
AUTO-animation
X
X
X
Slave mode
1
DMX Mode
2. Choose a unit to function as Master mode, set dipswitch to select
Sound Active or AUTO mode. The others must be set to Slave mode, set
dipswitch to select Slave mode.
Slave units set #3 on
3. Use standard XLR microphone cable chain your units together via the
XLR connector on the rear of the units. For longer cable runs we suggest
a terminator at the last fixture.
4. Turn on the all units' power, the units begin to reset, then the units
begin working. The slave units will react like the master unit.
5. The units will react to the low frequencies of music via the internal
microphone. Adjust the audio sensitivity knob on the back of the master
unit to make the unit more or less sensitive in sound active. The panel
has LED indicating for sound active.
DMX512
1. Install the units in a suitable position (laying or appending).
2. Use standard XLR microphone cable chain your units together via the
XLR connector on the rear of the units. For longer cable runs we suggest
a terminator at the last fixture.
3. Assign a DMX address to each the unit using dipswitches; see the
"DMX Address Quick Reference Char». (All units set to #1 and #10 ON
will be OK)
4. Turn on all units' power, the units begin to reset and then they start
working.
5. Use DMX console to control your units.
DMX address calculation
For DMX mode, DMX512 address from #1 to 9# dipswitches must be set,
the address is set from 1 to 511. Each dipswitch represents a binary
value.
No.
Digital No.
1st
1
2nd
2
3rd
4
4th
8
5th
16
No.
Digital No.
6th
32
7th
64
8th
128
9th
256
10th
Set to 0
Page 2