G
Important for U. K. Customers!
GB
The wires in this mains lead are coloured in ac cor-
dance with the follow ing code:
green/yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug, pro-
ceed as follows:
1. The wire which is coloured green and yellow must
be con nected to the terminal in the plug which is
mark ed with the letter E or by the earth symbol
or coloured green or green and yellow.
2. The wire which is coloured blue must be con-
nected to the terminal which is marked with the
letter N or coloured black.
3. The wire which is coloured brown must be con -
nected to the terminal which is marked with the
letter L or coloured red.
Warning — This appliance must be earthed.
If the units are to be put out of operation de -
finitively, take them to a local recycling plant
for a disposal which is not harmful to the envi-
ronment.

3 Applications

The colour cameras TVCCD-190COL and TVCCD-
190HCOL (high resolution) and the corresponding
power supply units are especially designed for use in
video surveillance systems. The one-cable technique
only requires a single coaxial cable for connecting the
camera to the power supply unit as the coaxial cable
allows both power supply and video signal transmis-
sion.
The cameras are weatherproof (IP 68) and are
there fore also suitable for outdoor applications. The
power supply unit must in any case be operated in -
doors.
When darkness falls (illuminance below 10 lux) the
42 infrared LEDs illuminate the surveillance area up to
50 m. If the brightness falls below 2 lux, the cameras
switch over to black-and-white reproduction.
8
4 Mounting
To find the optimum place of mounting, a trial run must
be made. For this purpose set the camera into opera-
tion for the time being according to chapter 5.
1) For removing the sunshield, release the central
screw of three screws (2) on the sunshield. Then
remove the sunshield from the guide rail back-
wards.
2) Screw the supplied bracket into one of the threaded
jacks of the camera and lock it with the knurled nut
(7):
for wall mounting into the lower threaded jack (12)
,
of the camera housing (as in fig.1),
for ceiling mounting into the threaded jack (3) of the
sunshield or – with the sunshield removed – into
the upper threaded jack of the camera housing.
3) Mount the bracket with the supplied dowels and
screws at a suitable place of the wall or ceiling.

5 Setting into Operation

1) Connect the cable (4) of the camera to the jack TO
CAMERA (19) of the power supply unit. The length
of the cable is 30 m. It may be extended up to
500 m when using a high-quality cable:
Cable type
RG-58U
RG-59U
RG-6U
The following cables from MONACOR are suitable
up to 350 m:
VCC-59, VCC-59/SW, VCC-59/WS, VCC-259/SW
2) Connect the video output VIDEO OUT TO MONI-
TOR (18) of the power supply unit via a 75 Ω
coaxial cable to the video input jack of the monitor
or a camera switcher or video splitter. Observe the
correct 75 Ω termination.
3) Connect the plug of the mains cable (15) to a
socket (230 V~/50 Hz) and switch on the power
supply unit with the switch POWER (14). The
power LED (13) will light up.
Max. cable length
200 m
350 m
500 m