NOTE FOR RECHARGEABLE SYSTEMS ONLY:
If your dog is not responding to the correction, the rechargeable
system has the option of setting the correction level on the
wall transmitter for Low, Medium, or High. The factory setting is
Medium. If you want to change the level:
1. Turn the Field Width knob to the "off" position. Remove the
knob, the four cover screws and the front cover.
2. The jumper in the upper right corner of the transmitter
can
be moved to the right for the Low setting or completely
removed for the High setting.
3. Replace the transmitter cover and the four cover screws
4. Install the knob with the pointer to the "off" position.
5. Retest the signal field width as described in Step 10.
NOTE: If the transmitter is set on High, there will be
no pre-correction warning tone.
B. System Test Procedure:
Whenever you experience a malfunction, you will need to do a Test Loop to determine which com-
ponent - collar, wall transmitter, or yard wire - is not working. To perform the Test Loop procedure:
1. Make a test loop using a piece of wire at least 4 meters in length.
INDICATOR LIGHT
SMART DOG
2. Remove the existing wire from your wall transmitter.
Field
Width
3. Insert the two ends of the test loop wire into the wall transmitter.
4. Turn the field width knob to the 9 o'clock position or a low set-
ting.
5. Place the test light on the collar receiver. With the collar in hand,
move outside the field and approach the test loop. Make a mental
note of the distance between the collar and the wire when the collar
activates.
6. Turn the field width knob to 12 o'clock or a medium setting.
7. Back away from the wire and approach it again. Determine the
distance between the collar and the wire when the collar activates.
The distance should be greater on the medium range setting.
8. If more than one collar receiver is used with the system, repeat the above test on each collar.
Results of System Test Procedures:
If there is no red light on the wall transmitter with the test loop wire in place, the wall transmitter is
malfunctioning.
If the red light is solid on the wall transmitter, but the collar does not activate on the test loop wire,
the collar receiver is not working. Change or recharge the battery in the collar receiver and repeat
the test.
If the red light is solid on the wall transmitter and the collar receiver activates as you approach the
test loop wire, the problem is in the yard wire.