Working with Automatic Levelling
Position the measuring tool on a level and firm support, attach
it to the holder 20 or to the tripod 15.
After switching on, the levelling function automatically com-
pensates irregularities within the self-levelling range of ±4°.
The levelling is finished as soon as the laser beams do not
move any more.
If automatic levelling is not possible, e.g. because the surface
on which the measuring tool stands deviates by more than 4°
from the horizontal plane, the laser lines will begin to flash
quickly.
In case of ground vibrations or position changes during oper-
ation, the measuring tool is automatically levelled in again. To
avoid errors, check the position of the horizontal and vertical
laser line with regard to the reference points upon re-level-
ling.
Working without Automatic Levelling
For work without automatic levelling, slide the On/Off switch
2 to position "
on". When automatic levelling is switched
off, the laser lines flash slowly.
When the automatic levelling is switched off, the measuring
tool can be held by hand or placed on an inclined surface. In
cross-line operation, the two laser lines do not necessarily run
at a right angle to each other.
Levelling Accuracy
Influences on Accuracy
The ambient temperature has the greatest influence. Espe-
cially temperature differences occurring from the ground up-
ward can divert the laser beam.
As thermal fluctuation is largest close to the ground, the
measuring tool, if possible, should be mounted on a commer-
cially available tripod and placed in the centre of the working
area.
In addition to external influences, device-specific influences
(e.g. falls or heavy impacts) can also lead to deviations. For
this reason, check the levelling accuracy each time before be-
ginning work.
First, check both the height as well as the levelling accuracy of
the horizontal laser line, then the levelling accuracy of the ver-
tical laser line.
Should the measuring tool exceed the maximum deviation
during one of the tests, please have it repaired by a Bosch af-
ter-sales service.
Checking the Height Accuracy of the Horizontal Line
For this check, a free measuring distance of 5 m on a firm sur-
face between two walls A and B is required.
– Mount the measuring tool onto the holder or a tripod, or
place it on a firm and level surface close to wall A. Switch
the measuring tool on.
Bosch Power Tools
A
5 m
– Direct the laser against the close wall A and allow the meas-
uring tool to level in. Mark the centre of the point where the
laser lines cross each other on the wall (point I).
A
180°
– Turn the measuring tool by 180°, allow it to level in and
mark the cross point of the laser lines on the opposite wall
B (point II).
– Without turning the measuring tool, position it close to
wall B. Switch the measuring tool on and allow it to level in.
A
– Align the height of the measuring tool (using a tripod or by
underlaying, if required) in such a manner that the cross
point of the laser lines is projected against the previously
marked point II on the wall B.
A
d
– Without changing the height, turn around the measuring
tool by 180°. Direct it against the wall A in such a manner
English | 15
B
B
B
B
180°
1 609 92A 3G0 | (24.8.16)