12 Device Information

1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529
2.2
Installation Location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Brine (heat source)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow)
3.3
Heat output / COP
3.4
Sound power level to DIN 12102
3.5
Heating water flow with an internal pressure differential of m³/h / Pa
3.6
Brine throughput with an internal pressure
differential (heat source) of
3.7
Refrigerant; total filling weight
3.8
Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos 
5.4
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
7.4
Max. operating overpressure (heat source/heat sink)
1. These data indicate the size and capacity of the system according to EN 14511 (5K at A7). For an analysis of the economic and energy efficiency of the system, the bivalence
point and the regulation, should also be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on the maintenance, start-up
and operation can be found in the respective sections of the installation and operating instructions.
The specified values have the following meaning, e.g. B10/W55: External air temperature 10 °C and heating water flow temperature 55 °C.
2. Note that additional space is required for pipe connections, operation and maintenance.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump manager must always be ready for operation.
www.dimplex.de
°C
°C
at B0 / W35
K
1
at B0 / W35
kW / ---
1
at B0 / W45
kW / ---
dB(A)
m³/h / Pa
type / kg
type / litres
2
H x W x L mm
Inch
Inch
kg
V / A
1
B0 W35
kW
A
A / ---
4
bar
452232.66.13 · FD 9603
SI 5ME
SI 7ME
SI 9ME
IP 20
IP 20
IP 20
Indoors
Indoors
Indoors
Up to 58
Up to 58
Up to 58
-5 to +25
-5 to +25
-5 to +25
Mono-ethyl-
Mono-ethyl-
Mono-ethyl-
ene glycol
ene glycol
ene glycol
25%
25%
25%
5.0
5.0
5.0
4,9 / 3,8
6,3 / 3,7
8,9 / 3,8
4,6 / 2,8
5,7 / 2,9
8,5 / 2,8
54
55
56
0,85 / 6500
1,1 / 10000
1,5 / 9200
1,2 / 16000
1,7 / 29500
2,0 / 20000
R407C / 1.2
R407C / 1.4
R407C / 1.7
Polyolester
Polyolester
Polyolester
(POE) / 1.0
(POE) / 1.0
(POE) / 1.1
805  650 
805  650 
805  650 
462
462
462
G 1¼" exter-
G 1¼" exter-
G 1¼" exter-
nal
nal
nal
G 1¼"
G 1¼"
G 1¼"
external
external
external
109
111
118
230 / 16
230 / 16
230 / 20
1,30
1,58
2,22
24
26
38
7,1 / 0,8
8,6 / 0,8
12,1 / 0,8
3
3
3
No
No
No
1
1
1
Internal
Internal
Internal
3,0
3,0
3,0
SI 5ME - SI 14ME
SI 11ME
SI 14ME
IP 20
IP 20
Indoors
Indoors
Up to 58
Up to 58
-5 to +25
-5 to +25
Mono-ethyl-
Mono-ethyl-
ene glycol
ene glycol
25%
25%
5.0
5.0
10,8 / 3,9
15,3 / 3,9
10,0 / 2,9
15,0 / 3,2
56
56
1,9 / 15000
2,7 / 20500
2,5 / 18000
3,6 / 20900
R407C / 1.9
R407C / 2.2
Polyolester
Polyolester
(POE) / 1.4
(POE) / 1.9
805  650 
805  650 
462
462
G 1¼" exter-
G 1¼" exter-
nal
nal
G 1¼"
G 1¼"
external
external
122
130
230 / 25
230 / 32
2,69
3,83
38
45
14,6 / 0,8
20,8 / 0,8
3
3
No
No
1
1
Internal
Internal
3,0
3,0
EN-11