A-10 / ENGLISH
TROUBLESHOOTING
If the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Clarke Service Center
immediately for service.
TRIPPING THE CIRCUIT BREAKER
The Circuit Breaker (D) is located on the Control Panel; it protects the electrical circuit and brush motor from damage due to overload conditions. If the
circuit breaker is tripped try to determine the cause.
Brush Circuit Breaker (3 Amp) Possible cause may be:
1
Debris wrapped around the brush drive (remove debris)
2
Electrical short circuit (have your Clarke Service Center or qualifi ed electrician check the machine)
Once the problem has been corrected, push the button in to reset the circuit breaker. If the button does not stay in, wait 5 minutes and try again. If the
circuit breaker trips repeatedly, call your Clarke Service Center for service.
POOR WATER PICKUP
Possible causes may be:
1
Recovery Tank Full (empty recovery tank)
2
Recovery hose is kinked or damaged (replace the hose)
3
Recovery tank dome lid gasket leak (replace gasket)
4
Debris caught in vacuum shoe or recovery hose (clean vacuum shoe and recovery hose)
INADEQUATE SOLUTION FLOW
Possible causes may be:
1
Solution tank empty (fi ll solution tank)
2
Solution lines or screen clogged (fl ush lines and screen)
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model
Model No.
Voltage/frequency
Rated Current
Protection Class (electrical)
Protection Grade
Sound Pressure Level (ISO 11201)
Total Weight
Vibrations at the Hand Controls (ISO 5349-1)
Solution Tank Capacity
A-10 - FORM NO. 56041658 - Clean Track
EN
V/Hz
Amp
dB (A)/20μPa
lbs/kg
m/s
2
12
®
Clean Track
12
®
56265230
120 / 50-60
8
--
75
67 / 30
0.87m/s
2
5 gal (19l)
revised 11/07