Steca GRID 2000+ Instructions D'installation Et De Service page 49

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
IP 65
Isc
Junction box
LED
Master
Maximum Power Point
Master-slave principle
MPPT
MSD (ENS)
Multi-Contact
NEN1010
Open circuit voltage
Photovoltaic effect
PV
PV system
Reverse polarity protection
Short-circuit current (STC)
System configuration
Slave
Sleep mode
Solar module
Sub-D9
Stand-alone operation
String
Tamb
76.439 | 10.04
Shows how well a device is protected against
moisture and dust getting into it. Devices
with IP 65 can be set up in rooms and out-
doors.
Ishort-circuit, see short-circuit current.
Part of the master inverter that is used, for ex-
ample, for connecting the AC cable and data
cable of both the master and the slave.
Light Emitting Diode (display lamp)
An inverter in which several central functions
are implemented. These functions are also
meant for the so-called slave inverters but are
only implemented in the master device.
The DC voltage and the DC current of a solar
module at which the module produces the
most power.
A master controls 1 or  slaves
Maximum Power Point Tracking: a function of
the inverter that ensures that the solar mod-
ules work at the Maximum Power Point.
'Device for monitoring the grid with two
independent switching devices connected in
series.' A module that measures system im-
pedance. When the impedance fluctuates too
much the inverter is disconnected. The use
of this module is mandatory in Germany and
Austria.
Manufacturer of a particular kind of connec-
tors
A Dutch standard for electrical installations
The voltage that a module produces when no
electricity is flowing.
Converting light into electricity
Photovoltaics, see 'photovoltaic effect'.
A system in which solar modules produce
electricity.
A protective device that prevents the posi-
tive connection of the module from being
connected to the negative connection of the
inverter.
The current that the solar modules produce
under standard test conditions when they are
short-circuited.
The way in which several solar modules are
interconnected and jointly connected to the
inverter.
An inverter that is contolled by the master.
A operating mode of the inverter used to
minimise nighttime consumption.
A unit with a number of solar cells connected
in series. The solar cells convert light into volt-
age and current.
9-pole plug connector
The name for the operation of an inverter
without a grid voltage being present.
A number of solar modules connected in
series
The ambient temperature (in this case:
around the inverter)
49

Publicité

Table des Matières
loading

Table des Matières