Important Operating Notes; Operating Instructions - Truma Nova Leuchte NLZS Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Truma L.P. gas light NLZS with safety ignition device

Important operating notes

In case of a gas leakage or if you can smell gas, turn off gas
cylinder and have the system checked by an expert.
All fire protection regulations for appliances with an open
flame must be observed.

Operating instructions

Always observe the operating instructions and „Impor-
tant operating notes" prior to starting! The user is respon-
sible for the correct operation of the appliance.
Operating
1. Turn on gas cylinder and open quick-acting valve in the gas
supply line.
2. Take the shade (1) at the upper frame and tilt forward, open
the brown valve button (2) by turning to the left and ignite
with a match or lighter. Do not touch the mantle (3)!
Push the safety ignition button (4) and hold down for another
ten seconds.
3. Tilt up shade (1). Adjust the light intensity, if necessary, at
the valve button (2). For highest light intensity adjust the air
throttle LK (5)!
6
The air throttle LK (part no. 10000-39000) can also be
retrofitted to older lights.
Closing
Turn the valve button (2) all the way to the right. Close the
quick-acting valve in the gas supply line and turn off the gas
cylinder.
Mantle
Only the original Truma screw-on mantle guarantees a
maximum of brightness and durability!
Please handle the mantle with care and never touch the ash
frame! For packing the mantle has a protection cover, which
burns off smoking slightly.
Screw on a new mantle and burn off protection cover without
gas. Always replace a defective mantle to avoid damaging the
shade. Keep a spare mantle ready!
Remove remaining ash!

Publicité

Table des Matières
loading

Table des Matières