Télécharger Imprimer la page

Mounting The Ventilation Unit; Installing Roof Outlet - Renson Cbase Instructions De Montage

Masquer les pouces Voir aussi pour Cbase:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

C
base
en
5.3 • Mounting the ventilation unit
Put the number of desired sea-
ling caps and/or reductions
on the ventilation system and
cut them open at the desired
diameter. (Ø80 mm / Ø125
mm). Close off the other
extraction points on the unit
with sealing caps.
5.4 • Installing roof outlet
Install a roof outlet (max. 10Pa pressure loss at 250m³/h) or a wall outlet with a round connection
of Ø125 mm or Ø150 mm, as close (<2m) to the ventilation system as possible.
Connect the exhaust of the ventilation unit with the roof outlet by means of an isolated flexible
ventilation duct Ø125 / Ø150.
4 4
®
Connect the ventilation ducts
to the reductions by means of
fixing straps.
Unscrew the lid of the
ventilation box. Make sure
that the power is turned off!
Connect the power cable
and the cable for the three
position switch according to
the electrical wiring scheme
(section 6.1).
< 2 m