GROUP S.p.A.
C8.6 - Function CH-CH contact
(available from R.I.006)
This function can be used to assign a function to the
CH-CH contact; by default the active function is call
repetition and it is possible to select a contact time
(closure) of either 1, 3 or 5 seconds.
Alternatively, the parallel or external monitor
function can be activated; the contact will close for
the entire duration of a VIDEO call from the external
unit.
To activate the function:
- press the MENU key and use the
the 8-ADVANCED OPTIONS menu, then press 8;
8-ADVANCED
OPTIONS
- use the
keys to display the 6-FUNCTION
CH-CH CONTACT menu, then press 6;
6-FUNCTION
CH-CH CONTACT
- press 1 for the CALL REPLY function or 2 for the
EXTERNAL MONITOR function;
1-CALL REPLY
2-EXT. MONITOR
- if key 1 has been selected, the CONTACT TIME
(closure) will be requested; use keys
the selected time (1, 3 or 5 sec.);
CONTACT TIME:
1 SEC
CONTACT TIME:
3 SEC
Table of Simplebus TOP products
Art. 5714C R.I. 007 - Art. 5814C R.I. 002
BRACKETS
Art. 6114C R.I. 015
Art. 2608 R.I. 006 - Art. 2610 R.I. 008
DOOR-ENTRY
Art. 2619 R.I. 000 - Art. 2628 R.I. 005
PHONES
Art. 2638 R.I. 006
SWITCHING
Art. 1424 R.I. 002
DEVICES
MIXERS
Art. 4888C R.I. 013
Art. 1602 R.I. 027 - Art. 1602VCF R.I. 002
EXTERNAL
Art. 3340 R.I. 021 - Art. 3342 R.I. 021
UNITS
Art. 3070/A R.I. 010 Art. 3072/A R.I. 010
Art. 4660C R.I. 013
Art. 1998A R.I. 006 - Art. 1998V R.I. 001
SWITCHBOARDS
Art. 1998VC R.I. 001
SOFTWARE
Art. 1249/A R.I. 002
MT SB 01
42
C8.7 - Function main cps+sec
(available from R.I.006)
This is disabled by default.
CAUTION!
1 This function must remain disabled to prevent
malfunctioning when using switchboards, brackets,
door-entry phones, switching devices and mixers
with R.I. lower than the values indicated in the table
below.
2 This function must be activated on all switchboards
for the correct operation of Simplebus TOP systems
(with switching devices Art. 1424) which use both
keys to view
main and secondary switchboards.
For the correct operation of systems with main
and secondary switchboards, the system must be
fitted with TOP switchboards, brackets, door-entry
phones, switching devices and mixers, with R.I.
equal to or greater than the values listed in the table
on page 42.
To activate the function:
- press the MENU key and use the
the 8-ADVANCED OPTIONS menu, then press 8;
- use the
CPS+SEC menu;
to display
- press 7 to activate or deactivate the function;
R.I.
keys to view
8-ADVANCED
OPTIONS
keys to view the 7- FUNCTION MAIN
7- FUNCTION
MAIN CPS + SEC
SERVICE
ACTIVE
SERVICE
NON ACTIVE