How to configure a secondarya switchboard
- press the MENU key and use the
the 8-ADVANCED OPTIONS menu, then press 8:
8-ADVANCED
OPTIONS
- use the
keys to display the 3-TYPE OF
SWITCHBOARD menu, then press 3;
3- TYPE OF
SWITCHBOARD
- Press key 1;
* 1-SECONDARY
2-MAIN
The switchboard is configured as SINGLE CPS by
default.
It is now possible to configure it as SERIES CPS,
in fact the function 2-PARALLEL CPS IS NOT
AVAILABLE;
*1-SINGLE CPS
2-PARALLEL CPS
- to configure it as SERIES CPS, use the
display the 3-SERIES CPS menu, then press 3;
*3-SERIES CPS
- to configure it as MASTER, press 1; to configure it
as SLAVE, press 2;
1- MASTER
2- SLAVE
C8.4 - Self-ignition on/off (available from R.I.006)
This is disabled by default.
This function is only available for non-TOP Simplebus
systems and requires Art. 1259 for the cyclic
displaying of images from remote cameras.
This function can be used to activate or deactivate
the self-ignition transmitted by the internal units with
the switchboard in DAY mode.
To activate the function:
- press the MENU key and use the
view the 8-ADVANCED OPTIONS menu, then
press 8;
8-ADVANCED
OPTIONS
- use the
ON/OFF menu;
keys to view
- press 4 to activate or deactivate the function;
C8.5 -Triple call on/off (available from R.I.006)
This is disabled by default.
This function can be used to activate or deactivate
the triple call made by the switchboard to the internal
units.
The call will therefore take place on 3 consecutive
occasions (in the case of video calls: the first 2 will be
audio calls and the third will be a video call).
To activate the function:
- press the MENU key and use the
the 8-ADVANCED OPTIONS menu, then press 8;
keys to
- use the
ON/OFF menu;
- press 5 to activate or deactivate the function;
keys to
MT SB 01
keys to view the 4 SELF-IGNITION
4-SELF-IGNITION
ON/OFF
SERVICE
ACTIVE
SERVICE
NON ACTIVE
keys to view
8-ADVANCED
OPTIONS
keys to display the 5-TRIPLE CALL
5-TRIPLE CALL
ON/OFF
SERVICE
ACTIVE
SERVICE
NON ACTIVE
41