NOTE: All dimensions should be taken from the inside of the shower. Refer to the steam head and control Installation
Instructions for more dimensional and installation information.
Dual steam heads can be installed on opposite walls to improve steam distribution.
Determine the steam head location. Locate the steam head(s) 6" (152 mm) above the shower floor. The steam head
location should be within 25' (7.62 m) of the steam generator.
Determine the steam head location. Refer to the steam head Installation Instructions.
For single steam head installations, determine the steam control user interface location on the wall opposite the steam
head.
For dual steam head installations, determine the steam control user interface location on a different wall than the steam
heads. Locate the user interface as far from the steam heads as practical.
Locate the steam control user interface 60" (1524 mm) above the floor of the shower.
Verify that there is adequate clearance between the steam lines and any surrounding surfaces.
Kohler Co.
9
1601844-2-B