2. Determine the Location of the Steam Heads
Single Steam Head*
2" (51 mm) Min
6" (152 mm)
from Floor
*Applies to square and round steam heads.
WARNING: Risk of personal injury. Do not install the steam control user interface outside the steam enclosure.
The user interface must be installed within the enclosure to allow the sensors to regulate the temperature and
control the flow of steam.
WARNING: Risk of scalding. Do not block the steam head or locate the steam head near a seat or bench, as the
steam head is hot during operation and may scald the user.
IMPORTANT! Do not install the control directly above or in-line with the steam head.
NOTICE: When installing the control kit, allow room in the control cable for a drip loop. The drip loop will discourage
moisture from following the control cable to the steam generator.
1601844-2-B
Wall Stud
2-1/2" (64 mm) Min
Linear Steam Head
6" (152 mm)
from Floor
Dual Steam Head*
2" (51 mm) Min
2-1/2" (64 mm) Min
6" (152 mm) from Floor
Wall Stud
8
Wall Stud
2-1/2" (64 mm) Min
12-1/2" (318 mm) Min
Kohler Co.