4. Install the Steam Generator
Single Installation
Drain Pan
6" (152 mm) Min
Surrounding
Steam Generator
WARNING: Risk of property damage. There must be a minimum of 6" (152 mm) of air space surrounding the
steam generator on at least three sides. This provides an area for the heat generated by the unit to dissipate.
IMPORTANT! Install the steam generator in a well ventilated and temperature-controlled location.
NOTICE: For optimum performance, install the steam generator as close as possible to the steam head. The steam
generator must be installed within 25' (7.62 m) of the steam head.
Install the desired drain pan at the steam generator location. Kohler Co. recommends using a KOHLER drain pan.
IMPORTANT! If a KOHLER drain pan is NOT being used, construct the support blocks using heat-resistant material.
Position the steam generator on the support blocks.
Kohler Co.
Pressure Relief Valve
Water Inlet
Steam Outlet
Drain
RJ12 and
RJ45
Inputs
12"
(305 mm)
3/4"
(19 mm)
Min
11
Dual Installation
6" (152 mm) Min
Surrounding
Steam Generators
1601844-2-B