INSTALLATION MANUAL
1500NMUK / 1500PMUK Module Upgrade Kits
for Valor models 1500 and 1600 Linears
Use with Valor L1 1500, 1600 I or J Heater Models ONLY, to convert to 1500K or 1600K
Kit Contents
• 1500K Burner rail assembly 4007084AH and hard-
ware
• 1500K Burner module plate assembly (no receiver)
» 4008269 for natural gas
» 4008270 for propane
• Conversion label 4008271
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
Specifi cations
Models
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
* This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
4008257-01
©2020, Miles Industries Ltd.
L1 Series
1500KN
1500KP
1600KN
1600KN
Natural
Propane
0-4,500 feet*
30,000
30,000
19,000
21,000
3.5"
9.0"
5"
11"
10"
14"
DMS#36
DMS#51
51
30
220
160
WARNING
This upgrade kit shall be installed by a
qualifi ed service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fi re, explosion
or production of carbon monoxide
may result causing property damage,
personal injury or loss of life. The
qualifi ed service agency is responsible
for the proper installation of this kit. The
installation is not proper and complete
until the operation of the converted
appliance is checked as specifi ed in the
manufacturer's instructions supplied with
the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.