C
Leading zeros
F
Display test
U
Saving
1)
The setting range depends on the display range of the units:
Number
of digits
Unit version
2 digits
S202-x2/06/0R-001/0B-A0
3 digits
S202-x3/06/0R-001/0B-A0
4 digits
S202-x4/06/0R-001/0B-A0
5 digits
S202-x5/06/0R-001/0B-A0
Technical Data
Analog signal input
Resolution
Measurement rate
Measurement error
Temperature coefficient <50 ppm/°C
Current measurement
Input resistance
Input range
Voltage measurement
Input resistance
Input range
BAL S202 ANA M 1.0
Settings
Leading zeros not displayed*
Leading zeros displayed
No display test at power-on*
Display test at power-on
Demo operation mode
Saving parameters* (Set)
Not saving parameters (Escape)
Resetting to the default settings (Default)
16 Bit
ca. 4/s
0,02% of end value ±1 digit (25 °C)
approx. 22 Ω
0...±20 mA, max. ±100 mA
approx. 100 kΩ
0...±10 V, max. ±40 V
Setting range
-9...00...99
-99...000...999
-999...0000...9999
-9999...00000...99999
Monitor display
C
0. 0
C 000. 0
F ----
F 8. 8 . 8 . 8 .
F PLAY
U
set
U
ESC
U
dEF
Factory settings
menu items 3 and 7
10
100
1000
10000
31