BTL5-T1 _ _ -M _ _ _ _ -P-S103
Magnetostrictive Linear Position Sensor – Profile Style
4
Installation and connection (continued)
4.5
Electrical Connection
The BTL is attached via connectors.
Note the information on shielding and cable
routing on page 10.
4.5.1
Connecting the supply voltage, control and
data signals
The connection assignments are shown in Fig. 4-9,
Tab. 4-4 and Tab. 4-5.
Power
(pin)
4
3
1
Bus Out
Bus In
(socket)
(pin)
Fig. 4-9:
BKS pin assignment, BTL...-S103 connector, view on the
plug/socket side of the BTL
4.5.2
Connection example
PROFIBUS-DP
# 0
Master
A
B
4
5
4
5
2
2
Bus In
Bus Out
PROFIBUS-DP Interface
BTL5-T1...-S103
1
3
4
+24 V
BKS-S 48-15-CP-...
0 V
Fig. 4-10:
BTL5-T1...-S103 with master, connection example
www.balluff.com
All manuals and user guides at all-guides.com
BKS-S103/GS103-CP-...
4
5
2
2
# 1
Bus In
Bus Out
PROFIBUS-DP Interface
BTL5-T1...-S103
1
3
4
Control and data signals
Pin
BUS IN
1
VP +5 V (output)
2
RxD / TxD-N (A)
3
Data GND
4
RxD / TxD-P (B)
5
Shield
Tab. 4-4:
Control and data signals connection assignment
Supply voltage (external)
Pin
Power
1
+24 V
3
0 V (GND)
4
Shield
Tab. 4-5:
Supply voltage connection assignment
In this version the connections for power
supply, Bus In and Bus Out are located on
separate connectors.
BKS-S105-R01
390
220
390
4
5
4
5
2
# n
Bus In
PROFIBUS-DP Interface
BTL5-T1...-S103
1
BUS OUT
1
2
3
4
# 125
Bus Out
3
4
11