Airzone Aidoo Pro Modbus Aquarea M Guide D'intégration
Airzone Aidoo Pro Modbus Aquarea M Guide D'intégration

Airzone Aidoo Pro Modbus Aquarea M Guide D'intégration

Pour panasonic paw-azaw-mbs-m;

Publicité

Liens rapides

FR
Manuel
d'intégration
Aidoo Pro Modbus
Aquarea M
Pour PAW-AZAW-MBS-M
[Pour AZAI6WSPPN9]

Publicité

loading

Sommaire des Matières pour Airzone Aidoo Pro Modbus Aquarea M

  • Page 1 Manuel d’intégration Aidoo Pro Modbus Aquarea M Pour PAW-AZAW-MBS-M [Pour AZAI6WSPPN9]...
  • Page 2 Table des matieres PRECAUTIONS ET POLITIQUE ENVIRONNEMENTALE _______________________________________ 3 > Precautions ________________________________________________________________________________ 3 > Politique environnementale ___________________________________________________________ 3 PORT DE COMMUNICATION RS-485 ____________________________________________________________ 4 > Connexion _________________________________________________________________________________ 4 PROTOCOLE MODBUS _____________________________________________________________________________ 5 > Configuration de l’adresse esclave du dispositif Aidoo Pro Modbus Panasonic Aquarea M ___________________________________________________________________ 5 CODES DE FONCTION MODBUS __________________________________________________________________ 6 COMMANDES MODBUS ____________________________________________________________________________ 6...
  • Page 3 Precautions et politique environnementale PRECAUTIONS Pour votre propre sécurité et celle des dispositifs, veillez à respecter les instructions suivantes : • Ne pas manipuler le système avec les mains mouillées ou humides. • Effectuer tous branchements débranchements coupant préalable l’alimentation du système. •...
  • Page 4 Aucune CONNEXION Afin de veiller au bon fonctionnement des systèmes Airzone, vérifiez que seuls les câbles de communication (vert-bleu) soient connectés à chaque unité terminale des bus domotiques respectifs. À l’aide des vis, fixez les câbles aux différentes bornes, en respectant le code couleur.
  • Page 5 Protocole Modbus Modbus est un protocole de communication basé sur une architecture maître/esclave, qui organise l’information au niveau physique en formats ou groupes logique d’information. Chaque dispositif du réseau Modbus possède une seule et unique adresse. Le dispositif maître émet une commande dans une trame, laquelle contient l’adresse du dispositif ou des dispositifs destinataire(s) (esclaves).
  • Page 6 Codes de fonction Modbus Les commandes basiques de Modbus permettent de contrôler un dispositif pour modifier la valeur de l’un de ses registres (espace dans la mémoire) ou demander le contenu desdits registres ; selon les différents codes de fonction : Code Fonction Lecture des registres de sortie ou internes...
  • Page 7 COMMANDES D’ECRITURE Écriture d’un seul registre Octet Champ Adresse du système (1 - 247) (0 : Broadcast) Écriture d’un seul registre (6) Adresse de registre Données à écrire La réponse doit avoir toujours exactement le même format que la commande d’écriture, à condition qu’il ne se produise aucun type d’erreur.
  • Page 8 À condition qu’il ne se produise aucun type d’erreur, la réponse sera : Octet Champ Adresse du système (1 - 247) (0 : Broadcast) Écriture de plusieurs registres (16) Adresse de registre de départ Nombre de registres à écrire (N) COMMANDES DE LECTURE Question Octet...
  • Page 9 Gateway Setup for Panasonic CONFIGURATION RÉSEAU Sur l’écran principal de l’app «  Gateway Setup for Panasonic  », appuyez sur le bouton Configuration pour sélectionner la langue de travail de l’application et les unités de température. • Version. Indique la version de l’application. •...
  • Page 10 Après sélection du dispositif, le menu d’information s’affiche. • Nom. Nom du dispositif. • MAC. Adresse MAC du dispositif. • Firmware. Indique la version du dispositif. • Wi-Fi. Réseau disponible sur le dispositif. • Adresse IP. Affiche l’IP du dispositif. •...
  • Page 11 CONFIGURATION MODBUS RS-485 Accédez au menu de configuration pour modifier les paramètres suivantes du dispostif : • Modbus ID. Valeur comprise entre 1 et 255. • Vitesse (bps). 14 vitesses sont disponibles (100, 300, 500, 600, 1200, 2400, 4800, 7800, 9600 (par défaut), 19200, 38400, 57600, 76800 et 115200 bps).
  • Page 12 Registres Modbus AIDOO PRO MODBUS PANASONIC AQUAREA M (PAW-AZAW-MBS-M [AZAI6WSPPN9]) Read (R) Registers Description Values Operations Write (W) 0  Off 0x03, 0x04, Operation R & W 1  On 0x06, 0x10, 0x16 Outdoor actual temperature - 127 ºC ~ 127 ºC 0x03, 0x04 Outlet water temperature - 127 ºC ~ 127 ºC...
  • Page 13 Read (R) Registers Description Values Operations Write (W) HEAT Water Shift  - 5 ºC ~ 5 ºC Water  20 ºC ~ 75 ºC Room  10 ºC ~ 30 ºC Zone 1: [Water shift/room/pool] 0x03, 0x04, Pool  15 ºC ~ 35 ºC R &...
  • Page 14 Read (R) Registers Description Values Operations Write (W) HEAT Water Shift  5 ºC Water  75 ºC Room  30 ºC Zone 1: Max. set point Pool  35 ºC 0x03, 0x04 temperature COOL Water Shift  5 ºC Water ...
  • Page 15 Read (R) Registers Description Values Operations Write (W) Heat mode energy 0 ~ 65.534 W 0x03, 0x04 consumption [Cool mode / Heat recovery 0 ~ 65.534 W 0x03, 0x04 mode] energy consumption For future use Version of Modbus gateway Example: 0x0100  v1.0.1 0x03, 0x04 0 ...
  • Page 16 Read (R) Registers Description Values Operations Write (W) If K Series onwards: 1  Normal SG ready: Control pattern 2  HP Stop 0x03, 0x04 3  Capacity 1 4  Capacity 2 If K Series onwards: Water pressure 0x03, 0x04 0 ~ 5080 mbar If L Series onwards: Water inlet 2 temperature...
  • Page 17 Read (R) Registers Description Values Operations Write (W) Tank mode energy consumption (MSB) 0 ~ 4.294.967.294 kWh 0x03, 0x04 Tank mode energy consumption (LSB) Tank mode energy generation (MSB) 0 ~ 4.294.967.294 kWh 0x03, 0x04 Tank mode energy generation (LSB) 0 ...
  • Page 18 Read (R) Registers Description Values Operations Write (W) Compensation curve - Heat - 0x03, 0x04, 20 ºC ~ 75 ºC R & W Zone 1 - Min. temperature 0x06, 0x10, 0x16 Compensation curve - Heat 0x03, 0x04, - Zone 1 - Outdoor air min. - 20 ºC ~ 15 ºC R &...
  • Page 19 Read (R) Registers Description Values Operations Write (W) Compensation curve - Cool 15 ºC ~ 30 ºC 0x03, 0x04, - Zone 2 - Outdoor air max. R & W 0x06, 0x10, 0x16 temperature 0  Off Solar (actual) 0x03, 0x04 1 ...
  • Page 20 Read (R) Registers Description Values Operations Write (W) 0  No 0x03, 0x04, Opcional PCB connection R & W 1  Yes 0x06, 0x10, 0x16 0  No 0x03, 0x04, Buffer tank connection R & W 1  Yes 0x06, 0x10, 0x16 If NOT Big-A2W: 3 kW 0x03, 0x04,...
  • Page 21 Read (R) Registers Description Values Operations Write (W) Range water shift: [- 5 ºC ~ 5 ºC] Zone 2: [Water shift/water/ Range water: [20 ºC ~ 75 ºC 0x03, 0x04, room/pool] set temperature for R & W Range room: [10 ºC ~ 30 ºC] 0x06, 0x10, 0x16 heat mode Range pool: [15 ºC ~ 35 ºC]...
  • Page 22 Read (R) Registers Description Values Operations Write (W) 0  Off Powerful (actual) 0x03, 0x04 1  On 0  Off Quiet (actual) 0x03, 0x04 1  On 1  Range 1 Heat mode water set 2  Range 2 0x03, 0x04 temperature range 3 ...
  • Page 23 Read (R) Registers Description Values Operations Write (W) 1  No error Modbus meter gateway 2  Error 0x03, 0x04 3  Comm. not yet establish Heat mode energy If K Series onwards: 0x03, 0x04 consumption 0 ~ 65.534 W [Cool mode / Heat recovery If K Series onwards: 0x03, 0x04...
  • Page 24 Read (R) Registers Description Values Operations Write (W) If M Series: SG ready: Power consumption 0x03, 0x04, 500 W to 10000 W R & W (2-0): DHW 0x06, 0x10, 0x16 Resolution: 100W If M Series: SG ready: Power consumption 0x03, 0x04, 500 W to 10000 W R &...
  • Page 25 Read (R) Registers Description Values Operations Write (W) If M Series: 1  0.5 Kw 2  1.0 Kw 3  1.5 Kw 4  2.0 Kw 5  2.5 Kw 6  3.0 Kw 7  3.5 Kw SG ready power consumption: 8 ...
  • Page 26 Codes d’erreur AIDOO PRO MODBUS PANASONIC AQUAREA M (PAW-AZAW-MBS-M [AZAI6WSPPN9]) Diagnosis Abnormality / Abnormality Primary location to verify display Protection control judgement No abnormality detected · lndoor / Outdoor connection wire lndoor / Outdoor 90s after power · lndoor / Outdoor PCB capacity unmatched supply ·...
  • Page 27 Diagnosis Abnormality / Abnormality Primary location to verify display Protection control judgement Refrigerant low · Outdoor low pressure sensor (defective Continue for 5s pressure abnormality or disconnected) Refrigerant high · Outdoor high pressure sensor (defective Continue for 5s pressure abnormality or disconnected) ·...
  • Page 28 Diagnosis Abnormality / Abnormality Primary location to verify display Protection control judgement · Compressor tank temperature sensor · Clogged expansion valve or strainer Outdoor fan motor lock 2 times occurrence · Insufficient refrigerant abnormality within 30 minutes · Outdoor PCB ·...
  • Page 29 Diagnosis Abnormality / Abnormality Primary location to verify display Protection control judgement Outdoor heat exchanger · Outdoor heat exchanger temperature Continue for 5s temperature sensor sensor (defective or disconnected) abnormality Outdoor defrost sensor · Outdoor defrost sensor (defective or Continue for 5s abnormality disconnected) Indoor water outlet...
  • Page 30 airzonecontrol.com Marie Curie, 21 29590 Málaga Spain v. 100...