TROUBLE SHOOTING
Problem
Motor will not start.
The motor stops directly
after starting.
Pump runs but no suction.
Pump runs but poor suction.
Machine blows dust.
Abnormal sound from
machine.
All manuals and user guides at all-guides.com
Description
Part no
2107
Fine fi lter cellulose, with
2129
integrated fi lter cover
4110
42024
Other accessories — see Dustcontrol catalo-
42025
gue.
Service performed by other than Dustcontrol or its aut-
horized agent voids automatically the warranty. No other
warranty express or implied is applicable.
Fault
Machine not connected.
Incorrect fuse.
Thermal overload not set
correctly.
Hose not connected.
Hose plugged.
No plastic sack on the
cyclone.
Hole in the hose.
Plugged fi lter.
Hose too long or too small.
Hose is kinked.
Machine top is mounted
incorrectly.
Dust is packed in the
cyclone.
One of the fans is turned
off .
Filter is perforated or has
come loose.
DC 3800c Twin - 12
Part no
42026
Solution
Make sure connection.
Change to
correct circuit.
Electrician should adjust.
Connect the hose.
Find and remove block.
Mount the correct sack.
Change or repair hose.
Clean or change fi lter.
Change the hose.
Check and free.
Adjust the mounting.
Take off the top and clean
out.
Start it.
Check the fi lters and change
if necessary.
Order service.