KOMET MicroKom BluFlex ®
Meaning of what is indicated in the display
In difference mode, the display can be set to „zero" by pressing the R button.
In this way, the feed value can be read off directly. The current slide position can
then not be seen.
In absolute mode, the display always shows the current position of the slide. The
feed value cannot be read off directly but has to be calculated.
e.g. new value: 2.025 / old value: 2.015. Feed = 2.25 -2.015 = 0.01
5
5
5
switching the unit from millimetres to inches
or vice versa
To switch over, switch on the display unit.
It can be seen from the screen on the display unit under
6 what unit the value is shown in.
Press the R button and hold it depressed until the unit
in the display switches from inches to millimetres. The
switchover is then complete.
24
switching over the mode from absolute to
difference measurement
To switch over, switch on the display unit.
It can be seen from the screen on the display unit under
5 what mode the display is in, e.g. mode A
Press the ON button.
On the screen, the display switches to D.
In D mode, press and hold the R button until „0.0000"
is displayed on the screen. The switchover to D mode
is then complete.
Switching from D to A mode is completed after pressing
the ON button.
1
or vice versa
5
6
6
6