TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR
PRODUCT WITH THE POWER CONNECTED. DON'T JUST UNSCREW
THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM
THE RECEPTACLE.
TROUBLE
Power supply
is on, no light
are lit.
Power supply
is on, pump
on light is off,
failure light
is on.
Power supply
is on, pump
on light is on,
failure light is
off, and pump
short cycles
ON and OFF.
Power supply
is on, pump
on light is on,
failure light is
off, tap is open
and no flow.
Pump is off.
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you've
purchased the pump, please contact us at 514 337-4415, and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.
10
PROBABLE CAUSE
Unit may be defective.
Loss of prime due to a low
water level condition.
Water pipe obstructed from
water supply to pump.
Power cut-off by thermal protector.
Pump cannot reach proper
minimum operational pressure.
Loss of pressure due to leak
in the piping.
The water column to the highest
tap exceeds 50 feet.
FLUOMAC
ACTION
Test electrical therminals with
voltmeter. If there is no power,
replace the unit.
Wait for water level resume and
press reset buttom.
Clean obstruction and press reset
button.
Wait 10 minutes and press reset button
Clogged pump nozzle and/or venturi,
clean and press reset button.
Make sure all taps are closed and all
toilet valves are functionning.
If leak not found, install a back valve
after the Fluomac. If cycling stops, leak
is at the supply line. If cycling occurs,
leak is at suction line. Foot valve may
be defective or clogged. Replace.
Pressure of water of water column is
higher the cut-in pressure (26 PSI).
Re-install the unit at a higher level.